Print Report | Back to Sample Detail

Sample Record for 2019-10-23-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 99999 DEA: 0322222 QA Service Level:
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Michael Maksimovich Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-10-23-2
TL Number from the TL Form:
Sample Submitted By Organization: ZZCT - Sacramento DIME Development - AVS Testing Internal
Sample Organization Contact:
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/23/2019
Date that the sample was received by the laboratory/organization performing the testing: 10/23/2019
The quantity of what the sample constitutes: 300 cu yds
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex

Material Information

The concrete mix design number: 1234
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: 123456
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: Batch Plant
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2019-10-23-2-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Submitted By Organization: ZZCT - Sacramento DIME Development - AVS Testing Internal
Organization Address: 123 Street,
Organization City: Sacramento
Organization State: CA
Organization Zipcode:
Organization Email:
Organization Phone:
Data has not been verified.

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2019-10-23-2-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens10/23/201911/06/2019Jeffrey SulkaZZCT - Sacramento DIME Development - AVS Testing Internal
2019-10-23-2-3ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens10/23/201911/20/2019Jeffrey SulkaZZCT - Sacramento DIME Development - AVS Testing Internal