Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2019-10-14-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Annual Source Testing
Type of Material: Cementitious
Sample Taken Date: 10/14/2019
Date that the sample was received by the laboratory/organization performing the testing: 10/14/2019
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Type IL Cement
From where was the sample collected: Source
Laboratory sample identification: CM193901
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: LaFarge
DIME Test ID: 2019-10-14-3-2
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 01/08/2021
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 3 day test
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
3 days
|
The amount of flow
|
107 %
|
The amount of water used
|
46.5 %
|
Compressive strength of 1st specimen
|
3894 psi
|
Compressive strength of 2nd specimen
|
4094 psi
|
Compressive strength of 3rd specimen
|
4186 psi
|
Average Compressive strength (to nearest 10 psi)
|
4060 psi
|
DIME Test ID: 2019-10-14-3-3
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 01/08/2021
Date Tested: 10/22/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 7 day test
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
7 days
|
The amount of flow
|
107 %
|
The amount of water used
|
46.5 %
|
Compressive strength of 1st specimen
|
4382 psi
|
Compressive strength of 2nd specimen
|
4576 psi
|
Compressive strength of 3rd specimen
|
4556 psi
|
Average Compressive strength (to nearest 10 psi)
|
4500 psi
|
DIME Test ID: 2019-10-14-3-4
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 01/08/2021
Date Tested: 11/12/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test: 28 day test -- Specimen 3 was eliminated from the average for being outside allowable limits per Section 12 of ASTM C109
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
28 days
|
The amount of flow
|
107 %
|
The amount of water used
|
46.5 %
|
Compressive strength of 1st specimen
|
5540 psi
|
Compressive strength of 2nd specimen
|
5551 psi
|
Compressive strength of 3rd specimen
|
4859 psi
|
Average Compressive strength (to nearest 10 psi)
|
5550 psi
|
DIME Test ID: 2019-10-14-3-5
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 01/08/2021
Date Tested: 10/16/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specific gravity
|
3.15
|
Water Content
|
236 mL
|
The amount of flow (In percent)
|
86 %
|
The amount of water used (In percent)
|
67.43 %
|
Net Weight of Sample
|
848.4 grams
|
Air Content
|
7 %
|
DIME Test ID: 2019-10-14-3-6
Test Method: ASTM C188-15: Standard Test Method for Density of Hydraulic Cement
Verified Date: 01/08/2021
Date Tested: 11/12/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Density of hydraulic cement
|
3.145 g/cm^3
|
DIME Test ID: 2019-10-14-3-7
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Verified Date: 01/08/2021
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Type of Water Used
|
Type IV grade reagent water
|
Time in minutes of last penetration greater than 25mm (E)
|
134 min
|
Time in minutes of first penetration less than 25mm (H)
|
135 min
|
Penetration reading at time E
|
26 mm
|
Penetration reading at time H
|
25 mm
|
Initial time of setting
|
135 min
|
Final time of setting
|
no data
|
Method Used
|
Test Method A
|
DIME Test ID: 2019-10-14-3-8
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Verified Date: 01/08/2021
Date Tested: 10/22/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method Used
|
Test Method A
|
Test Time
|
155 seconds
|
Fineness
|
5030 cm^2/g
|
DIME Test ID: 2019-10-14-3-9
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 01/08/2021
Date Tested: 10/17/2019
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Corrected residue, % (Rc)
|
1.6 %
|
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325)
|
98.4 %
|