Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 043G6904 Cty SOL Rte 80 PM 13.9 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Quang Tran |
Date Reported: |
11/08/2019 |
|
Address: |
TL Number: |
95679 |
||
City: |
||||
Project Name: REMOVE BR DECK BY JETTING WATER, CONSTRUCT DECK AND APPROACH SLABS. |
||||
Prime Contractor: BRIDGEWAY CIVIL CONSTRUCTORS, INC. |
||||
Sample Taken Date: |
10/11/2019 |
Mix Design: |
1416245 |
|
Contractor: Unknown |
Location: SOLANO COUNTY IN FAIRFIELD AT DAN WILSON CREEK BRIDGE |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.02 | 12.69 | 75324 | 5935.7 | 1 |
2 | 4.01 | 12.62 | 77445 | 6136.7 | 1 |
3 | 4.01 | 12.62 | 77160 | 6114.1 | 1 |
DIME Test ID: 2019-10-11-3-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 6060
Age of specimen: 28 days
Certified By: Larry McCrum
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing