Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
DEA: No Project
QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2019-10-08-9
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/08/2019
Date that the sample was received by the laboratory/organization performing the testing: 10/16/2019
The quantity of what the sample constitutes: 5
A brief description of the sample: anchor bolts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales
Rocap Number(s):
Heat Number(s): 1201014100
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: ASTM F1554 GR.55 S1
Bolt Length(s): 5'
Nut Specification: n/a
Washer Specification: n/a
Finish: HDG and Plain
Diameter/Size: 2.5"
Bolt Mfg. Lot Number: 120101410020
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2019-10-08-9-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 10/21/2019
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 1 | 1201014100 | 0.5 | 0.196 | 59868 | 87329 | 28.5 | fsaylor |
| |
UTM
|
67kip
|
Temperature
|
72 f
|
DIME Test ID: 2019-10-08-9-2
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 10/21/2019
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 2 | 1201014100 | 0.499 | 0.196 | 59674 | 87605 | 28.5 | fsaylor |
| |
UTM
|
67kip
|
Temperature
|
72 f
|
DIME Test ID: 2019-10-08-9-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/21/2019
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201014100
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
60 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-10-08-9-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/21/2019
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201014100
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
60 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-10-08-9-5
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/21/2019
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201014100
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
60 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-10-08-9-6
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/21/2019
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201014100
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
60 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-10-08-9-7
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 10/21/2019
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201014100
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
60 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-10-08-9-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/21/2019
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201014100
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
60 in
|
Measurement Average
|
7.4 mils
|
DIME Test ID: 2019-10-08-9-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/21/2019
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201014100
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
60 in
|
Measurement Average
|
7.68 mils
|
DIME Test ID: 2019-10-08-9-10
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/21/2019
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201014100
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
60 in
|
Measurement Average
|
6.53 mils
|
DIME Test ID: 2019-10-08-9-11
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/21/2019
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201014100
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
60 in
|
Measurement Average
|
6.9 mils
|
DIME Test ID: 2019-10-08-9-12
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/21/2019
Date Tested: 10/18/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201014100
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
60 in
|
Measurement Average
|
7.08 mils
|