Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214032 DEA: 09378604 EFIS: 0918000080
QA Service Level: 1
DIST-CO-RTE-PM: 09-KER-58-R128.9/R135.1
Work Description: COLD PLANE AC PAVEMENT AND PLACE HMA.
Location Description: KERN COUNTY NEAR BORON FROM 1.3 MILES EAST OF CALIFORNIA CITY BOULEVARD TO 1.3 MILES WEST OF TWENTY MULE TEAM OVERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 3005 James Road, Bakersfield, CA 93308
Resident Engineer: Hin Hartanto Structure Rep.: Unknown
DIME Sample ID: 2019-09-18-18
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/18/2019
Date that the sample was received by the laboratory/organization performing the testing: 09/25/2019
The quantity of what the sample constitutes: 3 boxes
A brief description of the sample: 3/4 HMA-A-SP R25
From where was the sample collected: Manufacturer
Laboratory sample identification: 0562A-19
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Little Rock
DIME Test ID: 2019-09-18-18-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/04/2019
Date Tested: 09/26/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
no data
|
Corrected Asphalt Binder Content
|
4.37 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data
|
Moisture Content
|
no data
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
no data
|