Print Report | Back to Sample Detail

Sample Record for 2019-09-16-16

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214122 DEA: 081G1204 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-243-13.3/29.7
Work Description: COLD PLANE AC, PLACE RHMA-G AND RECESSED THERMOPLASTIC TRAFFIC STRIPE.
Location Description: RIVERSIDE COUNTY IN AND NEAR BANNING FROM 0.7 MILE NORTH OF BLACK MOUNTAIN TRAIL TO ROUTE 243/10 SEPARATION
Contractor Name: MATICH CORPORATION
Contractor Address: 1596 HARRY SHEPPARD BLVD, SAN BERNARDINO CA 92408
Resident Engineer: JONATHAN SKEITH Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-09-16-16
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 09/16/2019
Date that the sample was received by the laboratory/organization performing the testing: 09/25/2019
The quantity of what the sample constitutes: PSUE 6 bags
A brief description of the sample: 3/4 RHMA-G-SP
From where was the sample collected: Manufacturer
Laboratory sample identification: 0564G-19
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Robertsons - Cabazon, Cemex - Lytle Creek

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-33-0008, 91-36-0040
The fabricator's/manufacturer's product name for the sample: 3/4 RHMA-G-SP
The fabricator/manufacturer designation for the sample: CHP-68E
The plant number: Unknown
A detailed description of where the material sample was collected: Belt Cut at Matich Cabazon Plant
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown
Aggregate Mix Number:

Test Results

Test 1 of 9

DIME Test ID: 2019-09-16-16-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 10/07/2019
Date Tested: 09/26/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test: Virgin Aggregate Gradation
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? HMA Gradation
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 98 %
Cumulative percent passing the 1/2 in. sieve 88 %
Cumulative percent passing the 3/8 in. sieve 72 %
Cumulative percent passing the 1/4 in. sieve 56 %
Cumulative percent passing the #4 sieve 45 %
Cumulative percent passing the #8 sieve 25 %
Cumulative percent passing the #16 sieve 17 %
Cumulative percent passing the #30 sieve 13 %
Cumulative percent passing the #50 sieve 9 %
Cumulative percent passing the #100 sieve 6 %
Cumulative percent passing the #200 sieve 3.4 %

Test 2 of 9

DIME Test ID: 2019-09-16-16-2
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 10/07/2019
Date Tested: 09/28/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method 2 - Individual Fracture Determination
Aggregate Size and Fracture Type Coarse 1 and 2 Faced and Fine 1 Faced
Weighted average percentage of fractured, coarse, 2 faced particles 93 %
Weighted average percentage of fractured, coarse, 1 faced particles 97 %
Percentage of fractured, fine, 1 faced particles tested 100 %

Test 3 of 9

DIME Test ID: 2019-09-16-16-3
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 10/07/2019
Date Tested: 09/27/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.609
Absorption 1.4 %

Test 4 of 9

DIME Test ID: 2019-09-16-16-4
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 10/07/2019
Date Tested: 09/27/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity 2.608
Bulk specific gravity (SSD Basis) 2.643
Apparent specific gravity 2.701
Absorption 1.3 %

Test 5 of 9

DIME Test ID: 2019-09-16-16-5
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 10/14/2019.
Reason: retested

Test 6 of 9

DIME Test ID: 2019-09-16-16-6
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 10/07/2019
Date Tested: 09/27/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sand Equivalent 73

Test 7 of 9

DIME Test ID: 2019-09-16-16-7
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 10/07/2019
Date Tested: 09/28/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method B
Determination By Mass
Dimensional ratio used 1:5
Weighted percentage of particles (by mass) that were flat and elongated 2 %
Weighted percentage of particles (by mass) that were not flat and elongated 98 %

Test 8 of 9

DIME Test ID: 2019-09-16-16-8
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 10/07/2019
Date Tested: 09/28/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.608
Average uncompacted voids 47.1 %

Test 9 of 9

DIME Test ID: 2019-09-16-16-9
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 10/15/2019
Date Tested: 10/11/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Grading designation B
Mass of sample on No.12 sieve (after 500 revolutions) 3542 grams
Percent loss after 100 revolutions 6 %
Percent loss after 500 revolutions 29 %