Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 044Q0304 Cty SON Rte 1 PM 11.2, 11.20 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Jonathan Chi |
Date Reported: |
09/25/2019 |
|
Address: |
TL Number: |
239938 |
||
City: |
||||
Project Name: REPLACE FAILED 60" CMP CULVERT WITH 10'x10' PRECAST REINFORCED CONCRETE BOX |
||||
Prime Contractor: Valentine Corporation |
||||
Sample Taken Date: |
08/28/2019 |
Mix Design: |
4100A |
|
Contractor: Unknown |
Location: |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.35 | 125376 | 4422.4 | 1 |
2 | 6.02 | 28.45 | 126532 | 4447.5 | 1 |
DIME Test ID: 2019-08-28-12-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4430
Age of specimen: 28 days
Certified By: jasdev kumar
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing