Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214037 DEA: 120R2604 EFIS: 1218000073
QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-90-5.5/8.1,12.0/12.8
Work Description: COLD PLANE AC PAVEMENT, PLACE RHMA AND APPLY TRAFFIC STRIPES
Location Description: ORANGE COUNTY IN BREA, PLACENTIA, AND ANAHEIM FROM ROUTE 90/57 SEPARATION TO 0.1 MILE EAST OF ROSE DRIVE AND FROM 0.3 MILE NORTH OF ORANGETHORPE AVENUE TO ROUTE 91/90 SEPARATION
Contractor Name: ALL AMERICAN ASPHALT
Contractor Address: 1776 ALL AMERICAN WAY, CORONA, CA 91718-2229
Resident Engineer: IRVIN NGUYEN Structure Rep.: Unknown
DIME Sample ID: 2019-07-16-16
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Dispute Resolution
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/16/2019
Date that the sample was received by the laboratory/organization performing the testing: 08/08/2019
The quantity of what the sample constitutes: 8
A brief description of the sample: 1/2 inch RHMA-G
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Corona
DIME Test ID: 2019-07-16-16-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 12/17/2019
Date Tested: 08/13/2019
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Translab Internal lab id: 019-019
Sample: 1/2 inch RHMA-G (Dispute Resolution)
AASHTO T-209
Test Result Compliance:
Additional Comments When Verified:
Number of tests
|
2
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Water
|
Method Performed
|
no data
|
Mass of oven-dry sample in air for Sample 1
|
1579.0 grams
|
Mass of sample in water for Sample 1
|
931.0 grams
|
Mass of oven-dry sample in air for Sample 2
|
1562.0 grams
|
Mass of sample in water for Sample 2
|
924.0 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.439
|
Specific Gravity for Sample 2
|
2.451
|
Average Specific Gravity
|
2.445
|
Theoretical maximum density at 25°C (77°F)
|
no data
|