Sample Record for 2019-08-12-18
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 212501 DEA: 022E4804 EFIS: 0200000586
QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-96,263-103.1/103.6,56.8/57.2
Work Description: BRIDGE REPLACEMENT
Location Description: SISKIYOU COUNTY ABOUT 8 MILES NORTH OF YREKA ON ROUTE 96 FROM 0.5 MILE WEST TO 0.2 MILE EAST OF ROUTE 263 AND ON ROUTE 263 FROM 0.3 MILE NORTH OF SHASTA RIVER BRIDGE #02-0014 TO ROUTE 96
Contractor Name: Golden State Bridge
Contractor Address: 3701 Mallard Drive, Benicia, CA 94510
Resident Engineer: Nicole Mallory Structure Rep.: Andy O'Sullevan
Sample Information
DIME Sample ID: 2019-08-12-18
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 08/12/2019
Date that the sample was received by the laboratory/organization performing the testing: 08/20/2019
The quantity of what the sample constitutes: 1
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber
Material Information
Mfg. Lot Number(s): 17468-1
Material/Compound/Elastomer ID: na
Samples Representing: 11
Description (size): 3.5" x 14" x 14"
Comments: Unknown
Description (Number of Shims): 7
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: na
Test Results
Test 1 of 4
DIME Test ID: 2019-08-12-18-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 09/04/2019
Date Tested: 08/28/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
51
|
Reading #2
|
51
|
Reading #3
|
51
|
Reading #4
|
51
|
Reading #5
|
51
|
Mean
|
51
|
Test 2 of 4
DIME Test ID: 2019-08-12-18-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 09/04/2019
Date Tested: 09/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
5
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.06
|
Sample 1 Tear Strength
|
216.38
|
Sample 2 Median Thickness
|
0.062
|
Sample 2 Tear Strength
|
121.8
|
Sample 3 Median Thickness
|
0.066
|
Sample 3 Tear Strength
|
220.51
|
Sample 4 Median Thickness
|
0.064
|
Sample 4 Tear Strength
|
229.1
|
Sample 5 Median Thickness
|
0.056
|
Sample 5 Tear Strength
|
242.7
|
Median of the Tear Strength Values
|
220.51 lb/in
|
Test 3 of 4
DIME Test ID: 2019-08-12-18-5
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 08/28/2019
Date Tested: 08/28/2019
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 4 of 4
DIME Test ID: 2019-08-12-18-6
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 09/04/2019
Date Tested: 09/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
5
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.062
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
1769 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.065
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2512 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.062
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2540 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Sample 4 Median Thickness
|
0.059
|
Sample 4 Thickness all Within 0.003 inch?
|
Yes
|
Sample 4 Ultimate Tensile
|
2592 lbf/in^2
|
Sample 4 Elongation (350% Min)
|
Pass
|
Sample 5 Median Thickness
|
0.063
|
Sample 5 Thickness all Within 0.003 inch?
|
Yes
|
Sample 5 Ultimate Tensile
|
2472 lbf/in^2
|
Sample 5 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2512 lbf/in^2
|