Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212244 DEA: 044G8404 EFIS: 0413000051
QA Service Level: 1
DIST-CO-RTE-PM: 04-NAP-128-20.1/20.4
Work Description: REPLACE CAPELL CREEK BRIDGE
Location Description: NAPA COUNTY ABOUT 15 MILES EAST OF RUTHERFORD FROM 1.1 MILES EAST OF KNOXVILLE ROAD TO 0.3 MILE WEST OF CAPELL VALLEY CREST
Contractor Name: GORDON N BALL INC
Contractor Address: 333 CAMILLE AVENUE, ALAMO CA 94507
Resident Engineer: Darren Isada Structure Rep.: Nana Budu
DIME Sample ID: 2019-08-21-6
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Department Acceptance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 08/21/2019
Date that the sample was received by the laboratory/organization performing the testing: 09/03/2019
The quantity of what the sample constitutes: 3 ea assembly
A brief description of the sample: A325 HDG bolt assemblies
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name: Cappell Creek Bridge
The fabricator/manufacturer/facility name: Acrow Bridge
Rocap Number(s):
Heat Number(s):
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A325
Bolt Length(s):
Nut Specification: A563
Washer Specification: F436
Finish: Hot Dipped Galvanized
Diameter/Size:
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2019-08-21-6-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 09/16/2019
Date Tested: 09/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 1A | 416941A | 1.0000 | 90410 | 402.16 | 10.00 | A325 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
DIME Test ID: 2019-08-21-6-2
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 09/16/2019
Date Tested: 09/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 2A | 409581A | 1.0000 | 89823 | 399.55 | 10.00 | A325 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
DIME Test ID: 2019-08-21-6-3
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 09/16/2019
Date Tested: 09/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 3A | 407732A | 1.0000 | 89777 | 399.35 | 10.00 | A325 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
DIME Test ID: 2019-08-21-6-4
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 09/16/2019
Date Tested: 09/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 4A | 408029 | 1.0000 | 88881 | 395.36 | 10.00 | A325 Wedge Tensile | spaine |
| |
UTM
|
450kip
|
Temperature
|
no data
|
DIME Test ID: 2019-08-21-6-5
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 09/16/2019
Date Tested: 09/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 1A | 410347C | | 91000 | | Nut Proof Load | spaine |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
DIME Test ID: 2019-08-21-6-6
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 09/16/2019
Date Tested: 09/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 2A | 410347C | | 90994 | | Nut Proof Load | spaine |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
DIME Test ID: 2019-08-21-6-7
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 09/16/2019
Date Tested: 09/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 3A | 410347C | | 90985 | | Nut Proof Load | spaine |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
DIME Test ID: 2019-08-21-6-8
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 09/16/2019
Date Tested: 09/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 4A | 410347C | | 91057 | | Nut Proof Load | spaine |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
DIME Test ID: 2019-08-21-6-9
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 09/16/2019
Date Tested: 09/05/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 5A | 29395 | | 91033 | | Nut Proof Load | spaine |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
DIME Test ID: 2019-08-21-6-10
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 09/16/2019
Date Tested: 09/05/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 6A | 29706 | | 145518 | | Nut Proof Load | spaine |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
DIME Test ID: 2019-08-21-6-11
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 1 | 990582 | 0.498 | 0.195 | 120000 | 149070 | 17.5 | bewing |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|
DIME Test ID: 2019-08-21-6-12
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 2 | 990582 | 0.498 | 0.195 | 120000 | 140808 | 18.3 | bewing |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|
DIME Test ID: 2019-08-21-6-13
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 3 | 188227 | 0.499 | 0.196 | 120000 | 138985 | 18.4 | bewing |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|
DIME Test ID: 2019-08-21-6-14
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 4 | 188227 | 0.498 | 0.195 | 120000 | 138104 | 19.1 | bewing |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|
DIME Test ID: 2019-08-21-6-15
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
416941A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
3.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-08-21-6-16
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
409581A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
4.25 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-08-21-6-17
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
407732A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
5.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-08-21-6-18
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
408029A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
4 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-08-21-6-19
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
BG1402
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
2.75 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-08-21-6-20
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
BG 1365
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1.25 in
|
Bolt Length
|
3.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-08-21-6-21
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
410347C
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-08-21-6-22
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
410347C
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-08-21-6-23
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
410347C
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-08-21-6-24
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
410347C
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-08-21-6-25
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
29395
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-08-21-6-26
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
29706
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1.25 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-08-21-6-27
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
416941A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
3.5 in
|
Measurement Average
|
4.68 mils
|
DIME Test ID: 2019-08-21-6-28
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
409581A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
4.25 in
|
Measurement Average
|
4.25 mils
|
DIME Test ID: 2019-08-21-6-29
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
407732A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
5.5 in
|
Measurement Average
|
3.36 mils
|
DIME Test ID: 2019-08-21-6-30
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
408029A
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
4 in
|
Measurement Average
|
4.3 mils
|
DIME Test ID: 2019-08-21-6-31
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
BG1402
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
2.75 in
|
Measurement Average
|
2.3 mils
|
DIME Test ID: 2019-08-21-6-32
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
BG 1365
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1.25 in
|
Bolt Length
|
3.5 in
|
Measurement Average
|
3.19 mils
|
DIME Test ID: 2019-08-21-6-33
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
410347C
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.63 mils
|
DIME Test ID: 2019-08-21-6-34
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
410347C
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.44 mils
|
DIME Test ID: 2019-08-21-6-35
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
410347C
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.8 mils
|
DIME Test ID: 2019-08-21-6-36
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
410347C
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.77 mils
|
DIME Test ID: 2019-08-21-6-37
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
29395
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.47 mils
|
DIME Test ID: 2019-08-21-6-38
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
29706
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
1.25 in
|
Bolt Length
|
no data in
|
Measurement Average
|
6.57 mils
|
DIME Test ID: 2019-08-21-6-39
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D5066
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 TSI
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.71 mils
|
DIME Test ID: 2019-08-21-6-40
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D5066
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 TSI
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.59 mils
|
DIME Test ID: 2019-08-21-6-41
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D5066
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 TSI
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.94 mils
|
DIME Test ID: 2019-08-21-6-42
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D5066
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 TSI
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
4.15 mils
|
DIME Test ID: 2019-08-21-6-43
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D6542
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 P
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Measurement Average
|
5.2 mils
|
DIME Test ID: 2019-08-21-6-44
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
61061
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
WS
|
Size
|
1.25 in
|
Bolt Length
|
no data in
|
Measurement Average
|
5.15 mils
|
DIME Test ID: 2019-08-21-6-45
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
BG1402
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1 in
|
Bolt Length
|
2.75 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
30.1
|
Spacing
|
Ok
|
DIME Test ID: 2019-08-21-6-46
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
BG 1365
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 USA N
|
Size
|
1.25 in
|
Bolt Length
|
3.5 in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
27.75
|
Spacing
|
Ok
|
DIME Test ID: 2019-08-21-6-47
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D5066
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 TSI
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
40.6
|
Spacing
|
Ok
|
DIME Test ID: 2019-08-21-6-48
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
2A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D5066
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 TSI
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
38.95
|
Spacing
|
Ok
|
DIME Test ID: 2019-08-21-6-49
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
3A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D5066
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 TSI
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
40.75
|
Spacing
|
Ok
|
DIME Test ID: 2019-08-21-6-50
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
4A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D5066
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 TSI
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
41.05
|
Spacing
|
Ok
|
DIME Test ID: 2019-08-21-6-51
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
5A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
D6542
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
F436 P
|
Size
|
1 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
38.4
|
Spacing
|
Ok
|
DIME Test ID: 2019-08-21-6-52
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 09/16/2019
Date Tested: 09/10/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
6A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
61061
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
WS
|
Size
|
1.25 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
12
|
Spacing
|
Ok
|
DIME Test ID: 2019-08-21-6-53
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 09/16/2019
Date Tested: 09/13/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 5 | 188227 | 0.355 | 0.099 | 124250 | 139745 | 20.6 | svang |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|