Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
DEA: No Project
QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2019-08-21-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Acceptance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 08/21/2019
Date that the sample was received by the laboratory/organization performing the testing: 08/26/2019
The quantity of what the sample constitutes: 1
A brief description of the sample: 7/8" x 30" A449 Hex Bolts
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS Lindon UT
Rocap Number(s): NA
Heat Number(s): 3087319
Nut Mfg. Lot Number(s): NA
Washer Mfg. Lot Number(s): NA
Bolt Specification: ASTM A449
Bolt Length(s): 30"
Nut Specification: NA
Washer Specification: NA
Finish: Hot Dip Galvanized
Diameter/Size: 7/8"
Bolt Mfg. Lot Number: 56048-1
Rocap Test Requirement(s): NA
Lubricant Requirements(s): NA
DIME Test ID: 2019-08-21-3-1
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 09/06/2019
Date Tested: 09/06/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test: A449 Bolt 10 Deg. Head Broke OFF
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments | 1 | UNC 7/8 | 0.462 | 62885 | 62885 | 136115 | 131696 | 60843 | A449 Bolt 10 Deg. Head Broke OFF |
| |
UTM
|
400kip
|
Temperature
|
72
|
DIME Test ID: 2019-08-21-3-2
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 09/06/2019
Date Tested: 09/06/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
3087319
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A449
|
Size
|
.875 in
|
Bolt Length
|
30 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-08-21-3-3
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 09/06/2019
Date Tested: 09/06/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
3087319
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
KT A449
|
Size
|
.875 in
|
Bolt Length
|
30 in
|
Measurement Average
|
3.99 mils
|