Print Report | Back to Sample Detail

Sample Record for 2019-07-30-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212824 DEA: 051C3704 EFIS: 0512000135 QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-101-16.4
Work Description: PISMO CREEK SCOUR REPAIR PROJECT (BR 49-0015K)
Location Description: IN SAN LUIS OBISPO COUNTY IN PISMO AT PISMO CREEK BRIDGE
Contractor Name: BRIDGEWAY CIVIL CONSTRUCTORS, INC.
Contractor Address: 4950 ALLISON PARKWAY, SUITE A, VACAVILLE CA 95688
Resident Engineer: Lilian Bennetzen Structure Rep.: Sal Heredia

Sample Information

DIME Sample ID: 2019-07-30-9
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 07/30/2019
Date that the sample was received by the laboratory/organization performing the testing: 08/02/2019
The quantity of what the sample constitutes: 1
A brief description of the sample: Ductile Iron Casting
From where was the sample collected: Distributor
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DSI Dotson Iron

Material Information

Heat Number (s): 2039
Part Number (s): 68 19 246
Material Specification: A536
Grades: 65-45-12
Metal Foundry Manufacturer (Mill): Dotson iron casting
Prestressing Manufacturer: DSI

Test Results

Test 1 of 1

DIME Test ID: 2019-07-30-9-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 08/05/2019
Date Tested: 08/05/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
20390.4970.194484107868012Fred
UTM 67KIP
Temperature 72 F