Print Report | Back to Sample Detail

Sample Record for 2019-07-26-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212956 DEA: 080R3404 EFIS: 0812000072 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-38-30.9
Work Description: BRIDGE REHABILITATION AND UPGRADE BRIDGE RAILING TO STANDARDS
Location Description: SAN BERNARDINO COUNTY NEAR ANGELUS OAKS AT SANTA ANA RIVER BRIDGERAM
Contractor Name: RSB GROUP, INC.
Contractor Address: 20331 Lake Forest Dr, Lake Forest, CA 92630
Resident Engineer: Ken Tran Structure Rep.: Sylvia Stracner

Sample Information

DIME Sample ID: 2019-07-26-9
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/26/2019
Date that the sample was received by the laboratory/organization performing the testing: 07/31/2019
The quantity of what the sample constitutes: 1 box
A brief description of the sample: 1/2 HMA-A-SP R15
From where was the sample collected: Manufacturer
Laboratory sample identification: 0451A-19
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American Asphalt Corona

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number: Unknown
Sublot number: Unknown
HMA Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2019-07-26-9-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/02/2019
Date Tested: 08/01/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 4.86 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data