Sample Record for 2019-07-12-5
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 213650 DEA: 081E8504 EFIS: 0814000114
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-142-0.0/5.8
Work Description: COLD PLANE/OVERLAY, HMA DIKES, INSTALL MGS AND DRAINAGE FACILITIES
Location Description: SAN BERNARDINO COUNTY IN AND NEAR CHINO HILLS FROM ORANGE COUNTY LINE TO ROUTE 142/71 SEPARATION.
Contractor Name: All American Aspalt
Contractor Address: 400 E Sixth St., Corona, CA, 92879
Resident Engineer: Ehirim Dominic Okechukwu Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2019-07-12-5
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 07/12/2019
Date that the sample was received by the laboratory/organization performing the testing: 07/15/2019
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: 3/4 HMA-A-SP R15
From where was the sample collected: Manufacturer
Laboratory sample identification: 0338A-19
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American Asphalt Corona
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: 108835
The plant number: Unknown
A detailed description of where the material sample was collected: Belt Cut at Plant
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown
Aggregate Mix Number:
Test Results
Test 1 of 2
DIME Test ID: 2019-07-12-5-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 07/18/2019
Date Tested: 07/16/2019
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested?
|
Combined Gradation
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
96 %
|
Cumulative percent passing the 1/2 in. sieve
|
84 %
|
Cumulative percent passing the 3/8 in. sieve
|
70 %
|
Cumulative percent passing the #4 sieve
|
31 %
|
Cumulative percent passing the #8 sieve
|
14 %
|
Cumulative percent passing the #16 sieve
|
9 %
|
Cumulative percent passing the #30 sieve
|
6 %
|
Cumulative percent passing the #50 sieve
|
4 %
|
Cumulative percent passing the #100 sieve
|
2 %
|
Cumulative percent passing the #200 sieve
|
1.9 %
|
Test 2 of 2
DIME Test ID: 2019-07-12-5-2
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 07/18/2019
Date Tested: 07/16/2019
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: