Sample Record for 2019-06-14-4
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 212911 DEA: 081F9404 EFIS: 0815000067
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-79-R4.7/R10.6
Work Description: COLD PLANE, OVERLAY WITH RUBBERIZED HOT MIX ASPHALT (TYPE G)
Location Description: RIVERSIDE COUNTY FROM 0.1 MILE SOUTH OF MURRIETA HOT SPRINGS ROAD TO 0.1MILE NORTH OF ABELIA ROAD
Contractor Name: R J NOBLE COMPANY
Contractor Address: 15505 E Lincoln Ave, Orange, CA 92865
Resident Engineer: Mike Bergevin Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2019-06-14-4
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Department Acceptance
Type of Material: Aggregate
Sample Taken Date: 06/14/2019
Date that the sample was received by the laboratory/organization performing the testing: 06/17/2019
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: 3/4 inch combined agg
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: R J Noble
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-33-0014::CHANDLER - COLDWATER
The fabricator's/manufacturer's product name for the sample: 3/4 RHMA-G
The fabricator/manufacturer designation for the sample: 49R003ARSP-C
The plant number: Unknown
A detailed description of where the material sample was collected: HMA Plant Cold Feed
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown
Aggregate Mix Number:
Test Results
Test 1 of 2
DIME Test ID: 2019-06-14-4-1
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 06/25/2019
Date Tested: 06/18/2019
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Test 2 of 2
DIME Test ID: 2019-06-14-4-2
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 06/25/2019
Date Tested: 06/18/2019
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested?
|
Combined Gradation
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
97 %
|
Cumulative percent passing the 1/2 in. sieve
|
81 %
|
Cumulative percent passing the 3/8 in. sieve
|
61 %
|
Cumulative percent passing the #4 sieve
|
30 %
|
Cumulative percent passing the #8 sieve
|
16 %
|
Cumulative percent passing the #16 sieve
|
11 %
|
Cumulative percent passing the #30 sieve
|
8 %
|
Cumulative percent passing the #50 sieve
|
5 %
|
Cumulative percent passing the #100 sieve
|
4 %
|
Cumulative percent passing the #200 sieve
|
3.3 %
|