Print Report | Back to Sample Detail

Sample Record for 2019-05-20-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-05-20-26
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Acceptance
Type of Material: SMTL TM10 - Wire Rope Choker
Sample Taken Date: 05/20/2019
Date that the sample was received by the laboratory/organization performing the testing: 05/20/2019
The quantity of what the sample constitutes: 1
A brief description of the sample: Wire Rope
From where was the sample collected: Other
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: 04 Toll Bridge Paint Crew

Material Information

Reel Number: 1
Painter Name or ID: Hector, Carlos, Albert
Material Specification: ASTM A931
Size: 5/16 in
Wire Manufacturer: Cable More
Material Collected to Test: Operator

Test Results

Test 1 of 6

DIME Test ID: 2019-05-20-26-1
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 06/05/2019
Date Tested: 06/05/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Cable Pulled Out of Clamp
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67 KIP
Specimen Identification Wire Rope
Peak Load 10138 lbf
Operator S144256
Location of Failure Clamp

Test 2 of 6

DIME Test ID: 2019-05-20-26-2
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 06/05/2019
Date Tested: 06/05/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Cable Pulled Out of Clamp
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67 KIP
Specimen Identification Wire Rope
Peak Load 9528 lbf
Operator S147664
Location of Failure Clamp

Test 3 of 6

DIME Test ID: 2019-05-20-26-3
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 06/05/2019
Date Tested: 06/05/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Cable Pulled Out of Clamp
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67 KIP
Specimen Identification Wire Rope
Peak Load 7957 lbf
Operator S143084
Location of Failure Clamp

Test 4 of 6

DIME Test ID: 2019-05-20-26-4
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 06/05/2019
Date Tested: 06/05/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Cable Pulled Out of Clamp
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67 KIP
Specimen Identification Wire Rope
Peak Load 8955 lbf
Operator S144256
Location of Failure Clamp

Test 5 of 6

DIME Test ID: 2019-05-20-26-5
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 06/05/2019
Date Tested: 06/05/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Cable Pulled Out of Clamp
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67 KIP
Specimen Identification Wire Rope
Peak Load 9204 lbf
Operator S147664
Location of Failure Clamp

Test 6 of 6

DIME Test ID: 2019-05-20-26-6
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Verified Date: 06/05/2019
Date Tested: 06/05/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Cable Pulled Out of Clamp
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 F
UTM 67 KIP
Specimen Identification Wire Rope
Peak Load 7660 lbf
Operator S143084
Location of Failure Clamp