Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213852 DEA: 034F6004 EFIS: 0314000228
QA Service Level: 1
DIST-CO-RTE-PM: 03-NEV-80-1.2/R9.4
Work Description: REMOVE METAL BEAM GUARD RAIL AND REPLACE WITH CONCRETE BARRIER
Location Description: NEVADA COUNTY IN AND NEAR TRUCKEE AT VARIOUS LOCATIONS FROM 1.3 MILES WEST OF SODA SPRINGS OVERCROSSING TO 0.3 MILE EAST OF DONNER LAKE UNDERCROSSING
Contractor Name: ROAD AND HIGHWAY BUILDERS OF CALIFORNIA, INC.
Contractor Address: 175 SOLOMON CIR. #103, SPARKS, NV 89434
Resident Engineer: RANDY STELLHORN Structure Rep.: Unknown
DIME Sample ID: 2019-05-29-5
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 05/29/2019
Date that the sample was received by the laboratory/organization performing the testing: 06/03/2019
The quantity of what the sample constitutes: 85,733 lbs.
A brief description of the sample: #4,5,6 Epoxy coated
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CMC Rebar Brighton
Rebar Heat Number(s): 4-4078132 5-4085738 4086033 4086034 6-4085652
Rebar Epoxy Batch Number(s): 4-5 VD45300NA C190869
6- VB17543NA C190753
Rebar Coating Specification: ASTM A775
Rebar Size (#): 4,5,6
Rebar Coating Color: Green
Rebar Manufacturer: CMC Rebar
Rebar Coater: CMC Brighton
Rebar Powder Manufacturer: AkzoNobel
Release Number:
Quality Assurance Code:
DIME Test ID: 2019-05-29-5-1
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 06/06/2019
Date Tested: 06/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: #4 HT#4078132
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean
|
11
|
Second Bar Mean
|
10.54
|
Lower spec. limit LSL
|
7
|
Upper spec. limit USL
|
12
|
Bar # for First Bar
|
1
|
Bar # for Second Bar
|
2
|
Total mean value
|
10.77
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|
DIME Test ID: 2019-05-29-5-2
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 06/06/2019
Date Tested: 06/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: #5 HT#4086034
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean
|
9.62
|
Second Bar Mean
|
9.34
|
Lower spec. limit LSL
|
7
|
Upper spec. limit USL
|
12
|
Bar # for First Bar
|
1
|
Bar # for Second Bar
|
2
|
Total mean value
|
9.48
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|
DIME Test ID: 2019-05-29-5-3
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 06/06/2019
Date Tested: 06/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: #5 HT#4085738
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean
|
10.59
|
Second Bar Mean
|
11.67
|
Lower spec. limit LSL
|
7
|
Upper spec. limit USL
|
12
|
Bar # for First Bar
|
1
|
Bar # for Second Bar
|
2
|
Total mean value
|
11.13
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|
DIME Test ID: 2019-05-29-5-4
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 06/06/2019
Date Tested: 06/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: #5 HT#4086033
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean
|
10.34
|
Second Bar Mean
|
10.39
|
Lower spec. limit LSL
|
7
|
Upper spec. limit USL
|
12
|
Bar # for First Bar
|
1
|
Bar # for Second Bar
|
2
|
Total mean value
|
10.37
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|
DIME Test ID: 2019-05-29-5-5
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 06/06/2019
Date Tested: 06/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: #6 HT#4085652
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean
|
13.32
|
Second Bar Mean
|
9.24
|
Lower spec. limit LSL
|
7
|
Upper spec. limit USL
|
16
|
Bar # for First Bar
|
1
|
Bar # for Second Bar
|
2
|
Total mean value
|
11.28
|
Total number of values less than LSL
|
no data
|
Total number of values greater than USL
|
no data
|
DIME Test ID: 2019-05-29-5-6
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 06/06/2019
Date Tested: 06/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: #4 HT#4078132
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
5
|
Holidays Per Linear Foot of Bar
|
0
|
Holiday Test Pass/Fail
|
Pass
|
Bend Test Pass/Fail
|
Pass
|
DIME Test ID: 2019-05-29-5-7
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 06/06/2019
Date Tested: 06/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: #5 HT#4086034
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
5 ft
|
Holidays Per Linear Foot of Bar
|
0 holiday pe
|
Holiday Test Pass/Fail
|
Pass
|
Bend Test Pass/Fail
|
Pass
|
DIME Test ID: 2019-05-29-5-8
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 06/06/2019
Date Tested: 06/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: #5 HT#4085738
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
5
|
Holidays Per Linear Foot of Bar
|
0
|
Holiday Test Pass/Fail
|
Pass
|
Bend Test Pass/Fail
|
Pass
|
DIME Test ID: 2019-05-29-5-9
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 06/06/2019
Date Tested: 06/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: #5 HT#4086033
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
5
|
Holidays Per Linear Foot of Bar
|
0
|
Holiday Test Pass/Fail
|
Pass
|
Bend Test Pass/Fail
|
Pass
|
DIME Test ID: 2019-05-29-5-10
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 06/06/2019
Date Tested: 06/04/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: #6 HT#4085652
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
0
|
Total Length
|
5
|
Holidays Per Linear Foot of Bar
|
0
|
Holiday Test Pass/Fail
|
Pass
|
Bend Test Pass/Fail
|
Pass
|