Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 210037 DEA: 043G4424 EFIS: 0412000042
QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-80-R5.6/7.6
Work Description: WEST SPAN DAMPER BRACKET A325 BOLT TESTING
Location Description: SFOBB WEST SPAN
Contractor Name: CALIFORNIA ENGINEERING CONTRACTORS, INC.
Contractor Address: 20 Happy Valley Road, Pleasanton, CA 94566
Resident Engineer: Tom Larwin Structure Rep.: Sergio Gomez
DIME Sample ID: 2019-05-10-17
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 05/10/2019
Date that the sample was received by the laboratory/organization performing the testing: 05/15/2019
The quantity of what the sample constitutes: 2
A brief description of the sample: A354 BC ATR
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Atlanta Rod
Rocap Number(s):
Heat Number(s): 62147385
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A354 BC
Bolt Length(s): 12.5"
Nut Specification: na
Washer Specification: na
Finish: HDG
Diameter/Size: 1.25"
Bolt Mfg. Lot Number: 69857-003
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2019-05-10-17-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 1 | 62147385 | 0.505 | 0.2 | 134909 | 149310 | 18.1 | Steve |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|
DIME Test ID: 2019-05-10-17-2
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 2 | 62147385 | 0.504 | 0.2 | 134361 | 148890 | 17.3 | Steve |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|
DIME Test ID: 2019-05-10-17-3
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
62147385
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
ATLROD BC
|
Size
|
1.25 in
|
Bolt Length
|
12.5 in
|
Pitch Diameter
|
1.178 in
|
Pitch Diameter 2nd
|
1.178 in
|
DIME Test ID: 2019-05-10-17-4
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
62147385
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
ATLROD BC
|
Size
|
1.25 in
|
Bolt Length
|
12.5 in
|
Pitch Diameter
|
1.173 in
|
Pitch Diameter 2nd
|
1.173 in
|
DIME Test ID: 2019-05-10-17-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
62147385
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
ATLROD BC
|
Size
|
1.25 in
|
Bolt Length
|
12.5 in
|
Measurement Average
|
8.52 mils
|
DIME Test ID: 2019-05-10-17-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/24/2019
Date Tested: 05/23/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
62147385
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
ATLROD BC
|
Size
|
1.25 in
|
Bolt Length
|
12.5 in
|
Measurement Average
|
8.95 mils
|