Sample Record for 2019-04-26-15
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 209694 DEA: 080J0704 EFIS: 0800000282
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-215-0.6/1.7
Work Description: (Alternative Delivery) The CMGC project will reconstruct and improve interchange of I-215 and Barton Road in the City of Grand Terrace, CA.
Location Description: Grade separation at Intersection of I-215 and Barton Road near Grand Terrace, CA. ? On I-215 between I-10 and SR-60.
Contractor Name: Myers / Rados-Southern California Jobsite Office
Contractor Address: 12210 Michigan St., Suite D, Grand Terrace, CA 92313
Resident Engineer: Fereydoon Alipanah Structure Rep.: Tim Flores
Sample Information
DIME Sample ID: 2019-04-26-15
TL Number from the TL Form: 20190426B
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/26/2019
Date that the sample was received by the laboratory/organization performing the testing: 05/02/2019
The quantity of what the sample constitutes: 2
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 975-426B
Structure unique identifier: abutment 4 foundation stage 2
Structure name: abutment 4 foundation stage 2
The fabricator/manufacturer/facility name: Robertson Riverside
Material Information
The concrete mix design number: SC590B38
The truck number from where the sample was collected: 1155
The batch plant ticket number from where the sample was collected: 4424302
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: MYERS RADOS JV
A detailed description of where the material sample was collected: 185 cy
Where the material sample would have been placed if not sampled: abutment 4 foundation stage 2
From Lot No.: Unknown
Bag Lot No.: Unknown
Test Results
Test 1 of 1
DIME Test ID: 2019-04-26-15-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521 Cured in accordance with ASTM C511
Verified Date: 05/24/2019
Date Tested: 05/24/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Cross sectional area of cylinder 1
|
28.46 in^2
|
Cross sectional area of cylinder 2
|
28.46 in^2
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Compressive strength (to nearest 10 psi)
|
4330 psi
|
Average diameter of cylinder 1
|
6.02 in
|
Average diameter of cylinder 2
|
6.02 in
|
Compressive strength of cylinder 1
|
4318.7 psi
|
Compressive strength of cylinder 2
|
4344.3 psi
|
Maximum load on cylinder 1
|
122910 lb
|
Maximum load on cylinder 2
|
123640 lb
|
Type of fracture pattern of cylinder 1
|
1
|
Type of fracture pattern of cylinder 2
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
28 days
|