Print Report | Back to Sample Detail

Sample Record for 2019-04-24-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66667 DEA: JMFPP EFIS: 0019000043 QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-04-24-9
TL Number from the TL Form:
Sample Submitted By Organization: Granite Construction Company - Tracy
Sample Organization Contact: (209) 234-3571
Type of Sample: Aggregate Prequalification Program
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/24/2019
Date that the sample was received by the laboratory/organization performing the testing: 04/24/2019
The quantity of what the sample constitutes: 24 boxes
A brief description of the sample: for JMF verification
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction Company

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number: Unknown
Sublot number: Unknown
HMA Mix Number:

Test Results

Test 1 of 10

DIME Test ID: 2019-04-24-9-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 04/24/2019
Date Tested: 02/11/2019
Submitted By Organization: Granite Construction Company - Tracy
Organization Address: 37400 South Bird Road,
Organization City: Tracy
Organization State: CA
Organization Zipcode: 95304
Organization Email: christopher.escobar@gcinc.com
Organization Phone: (209) 234-3571
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Specific Gravity for Sample 1 2.486
Theoretical maximum density at 25°C (77°F) no data

Test 2 of 10

DIME Test ID: 2019-04-24-9-2
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 04/24/2019
Date Tested: 02/11/2019
Submitted By Organization: Granite Construction Company - Tracy
Organization Address: 37400 South Bird Road,
Organization City: Tracy
Organization State: CA
Organization Zipcode: 95304
Organization Email: christopher.escobar@gcinc.com
Organization Phone: (209) 234-3571
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Percent Air Voids 3.7 %
Percent Air Voids 2 3.5 %
Percent Air Voids 3 3.3 %
Percent Air Voids Average 3.6 %

Test 3 of 10

DIME Test ID: 2019-04-24-9-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 04/24/2019
Date Tested: 02/11/2019
Submitted By Organization: Granite Construction Company - Tracy
Organization Address: 37400 South Bird Road,
Organization City: Tracy
Organization State: CA
Organization Zipcode: 95304
Organization Email: christopher.escobar@gcinc.com
Organization Phone: (209) 234-3571
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity 2.379
Bulk Specific Gravity 2 2.371
Bulk Specific Gravity 3 2.381
Average Bulk Specific Gravity 2.377

Test 4 of 10

DIME Test ID: 2019-04-24-9-4
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 04/24/2019
Date Tested: 04/22/2019
Submitted By Organization: Granite Construction Company - Tracy
Organization Address: 37400 South Bird Road,
Organization City: Tracy
Organization State: CA
Organization Zipcode: 95304
Organization Email: christopher.escobar@gcinc.com
Organization Phone: (209) 234-3571
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 274 psi
Average Wet Tensile Strength 188 psi
Tensile Strength Ratio 69

Test 5 of 10

DIME Test ID: 2019-04-24-9-5
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/24/2019
Date Tested: 02/11/2019
Submitted By Organization: Granite Construction Company - Tracy
Organization Address: 37400 South Bird Road,
Organization City: Tracy
Organization State: CA
Organization Zipcode: 95304
Organization Email: christopher.escobar@gcinc.com
Organization Phone: (209) 234-3571
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 5.40 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test 6 of 10

DIME Test ID: 2019-04-24-9-6
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Verified Date: 04/24/2019
Date Tested: 04/22/2019
Submitted By Organization: Granite Construction Company - Tracy
Organization Address: 37400 South Bird Road,
Organization City: Tracy
Organization State: CA
Organization Zipcode: 95304
Organization Email: christopher.escobar@gcinc.com
Organization Phone: (209) 234-3571
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A) 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B) 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A) 12.56 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B) 11.52 mm
Stripping Inflection Point (Wheel A) >25000
Stripping Inflection Point (Wheel B) >25000

Test 7 of 10

DIME Test ID: 2019-04-24-9-7
Test Method: AASHTO T329-13: Standard Method of Test for Moisture Content of Asphalt Mixtures by Oven Method (Moisture Content)
Verified Date: 04/24/2019
Date Tested: 02/11/2019
Submitted By Organization: Granite Construction Company - Tracy
Organization Address: 37400 South Bird Road,
Organization City: Tracy
Organization State: CA
Organization Zipcode: 95304
Organization Email: christopher.escobar@gcinc.com
Organization Phone: (209) 234-3571
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Moisture Content 0.00 %
Percent Change 0 %

Test 8 of 10

DIME Test ID: 2019-04-24-9-8
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 07/01/2019
Date Tested: 07/01/2019
Submitted By Organization: Granite Construction Company - Tracy
Organization Address: 37400 South Bird Road,
Organization City: Tracy
Organization State: CA
Organization Zipcode: 95304
Organization Email: christopher.escobar@gcinc.com
Organization Phone: (209) 234-3571
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Percent Air Voids 4.0 %

Test 9 of 10

DIME Test ID: 2019-04-24-9-9
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/01/2019
Date Tested: 07/01/2019
Submitted By Organization: Granite Construction Company - Tracy
Organization Address: 37400 South Bird Road,
Organization City: Tracy
Organization State: CA
Organization Zipcode: 95304
Organization Email: christopher.escobar@gcinc.com
Organization Phone: (209) 234-3571
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Water
Specific Gravity for Sample 1 2.486
Theoretical maximum density at 25°C (77°F) no data

Test 10 of 10

DIME Test ID: 2019-04-24-9-10
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/01/2019
Date Tested: 07/01/2019
Submitted By Organization: Granite Construction Company - Tracy
Organization Address: 37400 South Bird Road,
Organization City: Tracy
Organization State: CA
Organization Zipcode: 95304
Organization Email: christopher.escobar@gcinc.com
Organization Phone: (209) 234-3571
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 5.00 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data