Print Report | Back to Sample Detail

Sample Record for 2019-04-12-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 66667 DEA: JMFPP EFIS: 0019000043 QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-04-12-10
TL Number from the TL Form: HDQTRS Lab
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 04/12/2019
Date that the sample was received by the laboratory/organization performing the testing: 04/22/2019
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: Sized Untreated Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification: 019-005-Agg 19-JMFPP-0089
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Deer Creek Porterville

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-54-0021::DEER CREEK ASPHALT
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: From the plant
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown
Aggregate Mix Number:

Test Results

Test 1 of 7

DIME Test ID: 2019-04-12-10-1
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 05/17/2019
Date Tested: 05/17/2019
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method 2 - Individual Fracture Determination
Aggregate Size and Fracture Type Coarse 1 and 2 Faced
Weighted average percentage of fractured, coarse, 2 faced particles 91 %
Weighted average percentage of fractured, coarse, 1 faced particles 97 %

Test 2 of 7

DIME Test ID: 2019-04-12-10-2
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 05/16/2019
Date Tested: 05/13/2019
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Grading designation B
Mass of sample on No.12 sieve (after 500 revolutions) 4448 grams
Percent loss after 100 revolutions 2 %
Percent loss after 500 revolutions 11 %

Test 3 of 7

DIME Test ID: 2019-04-12-10-3
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 05/16/2019
Date Tested: 05/13/2019
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sand Equivalent 90

Test 4 of 7

DIME Test ID: 2019-04-12-10-4
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 05/17/2019
Date Tested: 05/17/2019
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.842
Average uncompacted voids 46.3 %

Test 5 of 7

DIME Test ID: 2019-04-12-10-5
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 05/17/2019
Date Tested: 05/17/2019
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method B
Determination By Mass
Dimensional ratio used 1:5
Weighted percentage of particles (by mass) that were flat and elongated 0.00 %
Weighted percentage of particles (by mass) that were not flat and elongated 100 %

Test 6 of 7

DIME Test ID: 2019-04-12-10-6
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 05/16/2019
Date Tested: 05/15/2019
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Bulk specific gravity 2.842
Bulk specific gravity (SSD Basis) 2.892
Apparent specific gravity 2.990
Absorption 1.7 %

Test 7 of 7

DIME Test ID: 2019-04-12-10-7
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 05/16/2019
Date Tested: 05/14/2019
Submitted By Organization: CT HQ - Sacramento Aggregate Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ryan.kester@dot.ca.gov
Organization Phone: (916) 227-7215
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.939
Absorption 0.8 %