Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
DEA: No Project
QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2019-04-22-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Verification
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/22/2019
Date that the sample was received by the laboratory/organization performing the testing: 04/24/2019
The quantity of what the sample constitutes: 5
A brief description of the sample: 2 1/2 x 5'-0" anchor bolt
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS
Rocap Number(s): none
Heat Number(s): 1201006811
Nut Mfg. Lot Number(s): n/a
Washer Mfg. Lot Number(s): n/a
Bolt Specification: F1554 Gr. 55
Bolt Length(s): 5'-0"
Nut Specification: n/a
Washer Specification: n/a
Finish: HDG/plain
Diameter/Size: 2 1/2" x 5'-0"
Bolt Mfg. Lot Number: UIS 120100681120
Rocap Test Requirement(s): none
Lubricant Requirements(s): none
DIME Test ID: 2019-04-22-1-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 1 | 1201006811 | 0.503 | 0.199 | 61411 | 86730 | 26.7 | Steve |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|
DIME Test ID: 2019-04-22-1-2
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 2 | 1201006811 | 0.502 | 0.198 | 63236 | 86990 | 26.4 | Steve |
| |
UTM
|
67KIP
|
Temperature
|
72 f
|
DIME Test ID: 2019-04-22-1-3
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201006811
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
48 in
|
Pitch Diameter
|
2.34 in
|
Pitch Diameter 2nd
|
2.3551 in
|
DIME Test ID: 2019-04-22-1-4
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201006811
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
48 in
|
Pitch Diameter
|
2.343 in
|
Pitch Diameter 2nd
|
2.3507 in
|
DIME Test ID: 2019-04-22-1-5
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201006811
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
48 in
|
Pitch Diameter
|
2.335 in
|
Pitch Diameter 2nd
|
2.3504 in
|
DIME Test ID: 2019-04-22-1-6
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201006811
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
48 in
|
Pitch Diameter
|
2.336 in
|
Pitch Diameter 2nd
|
2.3508 in
|
DIME Test ID: 2019-04-22-1-7
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201006811
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
48 in
|
Pitch Diameter
|
2.334 in
|
Pitch Diameter 2nd
|
2.3511 in
|
DIME Test ID: 2019-04-22-1-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201006811
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
48 in
|
Measurement Average
|
6.63 mils
|
DIME Test ID: 2019-04-22-1-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201006811
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
48 in
|
Measurement Average
|
7.04 mils
|
DIME Test ID: 2019-04-22-1-10
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201006811
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
48 in
|
Measurement Average
|
6.79 mils
|
DIME Test ID: 2019-04-22-1-11
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1D
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201006811
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
48 in
|
Measurement Average
|
6.74 mils
|
DIME Test ID: 2019-04-22-1-12
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1E
|
Rocap Number
|
no data
|
Heat Number(s)
|
1201006811
|
Mfg. Lot Number
|
no data
|
Finish Coating
|
Plain and A153 and F2329
|
Product Markings
|
YELLOW
|
Size
|
2.5 in
|
Bolt Length
|
48 in
|
Measurement Average
|
6.6 mils
|