Print Report | Back to Sample Detail

Sample Record for 2019-04-22-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-04-22-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Verification
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/22/2019
Date that the sample was received by the laboratory/organization performing the testing: 04/24/2019
The quantity of what the sample constitutes: 5
A brief description of the sample: 2 1/2 x 5'-0" anchor bolt
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS

Material Information

Rocap Number(s): none
Heat Number(s): 1201006811
Nut Mfg. Lot Number(s): n/a
Washer Mfg. Lot Number(s): n/a
Bolt Specification: F1554 Gr. 55
Bolt Length(s): 5'-0"
Nut Specification: n/a
Washer Specification: n/a
Finish: HDG/plain
Diameter/Size: 2 1/2" x 5'-0"
Bolt Mfg. Lot Number: UIS 120100681120
Rocap Test Requirement(s): none
Lubricant Requirements(s): none

Test Results

Test 1 of 12

DIME Test ID: 2019-04-22-1-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
112010068110.5030.199614118673026.7Steve
UTM 67KIP
Temperature 72 f

Test 2 of 12

DIME Test ID: 2019-04-22-1-2
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
212010068110.5020.198632368699026.4Steve
UTM 67KIP
Temperature 72 f

Test 3 of 12

DIME Test ID: 2019-04-22-1-3
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 1201006811
Mfg. Lot Number no data
Finish Coating Plain and A153 and F2329
Product Markings YELLOW
Size 2.5 in
Bolt Length 48 in
Pitch Diameter 2.34 in
Pitch Diameter 2nd 2.3551 in

Test 4 of 12

DIME Test ID: 2019-04-22-1-4
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 1201006811
Mfg. Lot Number no data
Finish Coating Plain and A153 and F2329
Product Markings YELLOW
Size 2.5 in
Bolt Length 48 in
Pitch Diameter 2.343 in
Pitch Diameter 2nd 2.3507 in

Test 5 of 12

DIME Test ID: 2019-04-22-1-5
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 1201006811
Mfg. Lot Number no data
Finish Coating Plain and A153 and F2329
Product Markings YELLOW
Size 2.5 in
Bolt Length 48 in
Pitch Diameter 2.335 in
Pitch Diameter 2nd 2.3504 in

Test 6 of 12

DIME Test ID: 2019-04-22-1-6
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) 1201006811
Mfg. Lot Number no data
Finish Coating Plain and A153 and F2329
Product Markings YELLOW
Size 2.5 in
Bolt Length 48 in
Pitch Diameter 2.336 in
Pitch Diameter 2nd 2.3508 in

Test 7 of 12

DIME Test ID: 2019-04-22-1-7
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) 1201006811
Mfg. Lot Number no data
Finish Coating Plain and A153 and F2329
Product Markings YELLOW
Size 2.5 in
Bolt Length 48 in
Pitch Diameter 2.334 in
Pitch Diameter 2nd 2.3511 in

Test 8 of 12

DIME Test ID: 2019-04-22-1-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 1201006811
Mfg. Lot Number no data
Finish Coating Plain and A153 and F2329
Product Markings YELLOW
Size 2.5 in
Bolt Length 48 in
Measurement Average 6.63 mils

Test 9 of 12

DIME Test ID: 2019-04-22-1-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) 1201006811
Mfg. Lot Number no data
Finish Coating Plain and A153 and F2329
Product Markings YELLOW
Size 2.5 in
Bolt Length 48 in
Measurement Average 7.04 mils

Test 10 of 12

DIME Test ID: 2019-04-22-1-10
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) 1201006811
Mfg. Lot Number no data
Finish Coating Plain and A153 and F2329
Product Markings YELLOW
Size 2.5 in
Bolt Length 48 in
Measurement Average 6.79 mils

Test 11 of 12

DIME Test ID: 2019-04-22-1-11
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) 1201006811
Mfg. Lot Number no data
Finish Coating Plain and A153 and F2329
Product Markings YELLOW
Size 2.5 in
Bolt Length 48 in
Measurement Average 6.74 mils

Test 12 of 12

DIME Test ID: 2019-04-22-1-12
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/03/2019
Date Tested: 05/02/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) 1201006811
Mfg. Lot Number no data
Finish Coating Plain and A153 and F2329
Product Markings YELLOW
Size 2.5 in
Bolt Length 48 in
Measurement Average 6.6 mils