Project Information

Project ID: 66667 DEA: JMFPP EFIS: 0019000043 QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-03-13-15
TL Number from the TL Form: D5
Sample Submitted By Organization: CT D05 - San Luis Obispo Field Laboratory
Sample Organization Contact: (559) 230-3109
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/13/2019
Date that the sample was received by the laboratory/organization performing the testing: 03/27/2019
The quantity of what the sample constitutes: 1/4 of Section 39 JMF verification samples
A brief description of the sample: Boxes of HMA, Cans of Asphalt and LAS
From where was the sample collected: Other
Laboratory sample identification: 19-J-015
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Papich Paso Robles

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: Unknown
Sublot number: Unknown

Test Results

Test 1 of 5

DIME Test ID: 2019-03-13-15-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Asphalt Binder Content)
Verified Date: 04/22/2019
Date Tested: 04/19/2019
Submitted By Organization: CT D05 - San Luis Obispo Field Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: doug.lambert@dot.ca.gov
Organization Phone: (559) 230-3109
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Asphalt Binder Content 5.09 %
Correction Factor (Percent by mass of HMA Specimen) no data

Test 2 of 5

DIME Test ID: 2019-03-13-15-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 04/22/2019
Date Tested: 04/17/2019
Submitted By Organization: CT D05 - San Luis Obispo Field Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: doug.lambert@dot.ca.gov
Organization Phone: (559) 230-3109
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
Mass Determination Air
Method Performed no data
Mass of container filled with water 7403.0 grams
Mass of oven-dry sample in air for Sample 1 2658.0 grams
Mass of container filled with the sample and water for Sample 1 8980.0 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.456
Theoretical maximum density at 25°C (77°F) no data

Test 3 of 5

DIME Test ID: 2019-03-13-15-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 04/22/2019
Date Tested: 04/18/2019
Submitted By Organization: CT D05 - San Luis Obispo Field Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: doug.lambert@dot.ca.gov
Organization Phone: (559) 230-3109
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.392
Bulk Specific Gravity 2 2.395
Bulk Specific Gravity 3 2.396
Average Bulk Specific Gravity 2.394

Test 4 of 5

DIME Test ID: 2019-03-13-15-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 04/22/2019
Date Tested: 04/19/2019
Submitted By Organization: CT D05 - San Luis Obispo Field Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: doug.lambert@dot.ca.gov
Organization Phone: (559) 230-3109
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 2.6 %
Percent Air Voids 2 2.5 %
Percent Air Voids 3 2.4 %
Percent Air Voids Average 2.5 %

Test 5 of 5

DIME Test ID: 2019-03-13-15-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 04/22/2019
Date Tested: 03/13/2019
Submitted By Organization: CT D05 - San Luis Obispo Field Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: doug.lambert@dot.ca.gov
Organization Phone: (559) 230-3109
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Average Dry Tensile Strength 284 psi
Average Wet Tensile Strength 204 psi
Tensile Strength Ratio 72