Print Report | Back to Sample Detail

Sample Record for 2019-02-27-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211650 DEA: 07293504 EFIS: 0713000215 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-138-58.8/60.2
Work Description: WIDEN ROUTE 138 AND CONSTRUCT DRAINAGE FACILITIES.
Location Description: LOS ANGELES COUNTY AT PEARBLOSSOM 0.3 MILE WEST OF 121ST STREET TO LONGVIEW ROAD
Contractor Name: C. A. Rasmussen, Inc.
Contractor Address: 28548 Livingston Avenue, Valencia, CA 91355
Resident Engineer: Fred Tieu Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-02-27-6
TL Number from the TL Form:
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 02/27/2019
Date that the sample was received by the laboratory/organization performing the testing: 02/28/2019
The quantity of what the sample constitutes: 750
A brief description of the sample: Asphalt Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan

Material Information

Performance Grade: PG64-16/10
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Asphalt Binder Supplier:
Multigrade:
Multigrade Type:

Test Results

Test 1 of 6

DIME Test ID: 2019-02-27-6-1
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Verified Date: 07/08/2019
Date Tested: 03/06/2019
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Is mass change based on one or two containers? Two
Average mass change -0.134 percent

Test 2 of 6

DIME Test ID: 2019-02-27-6-2
Test Method: AASHTO T228-09r13: Standard Method of Test for Specific Gravity of Semi-Solid Asphalt Materials (Specific Gravity)
Verified Date: 08/26/2019
Date Tested: 03/06/2019
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specific Gravity 1.020

Test 3 of 6

DIME Test ID: 2019-02-27-6-3
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 10/15/2019
Date Tested: 03/06/2019
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Phase RTFO residue
Phase Angle (δ) (for the 10 cycles) 87.1 degree
Dynamic Shear, G*/sin(δ) 3.99 kPa
(G*) x sin(δ)= no data

Test 4 of 6

DIME Test ID: 2019-02-27-6-4
Test Method: AASHTO T44-14: Standard Method of Test for Solubility of Bituminous Materials
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
Data has not been verified.

Test 5 of 6

DIME Test ID: 2019-02-27-6-5
Test Method: AASHTO T315-12: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
Data has not been verified.

Test 6 of 6

DIME Test ID: 2019-02-27-6-6
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
Data has not been verified.

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.