Sample Record for 2019-03-25-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 213126 DEA: 051J6604 EFIS: 0051800009
QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-192-8.0/12.5
Work Description: Replace bridges (3) and bridge rails (2)
Location Description: In Santa Barbara County in and near Santa Barbara, Montecito, and Carpinteria.
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: P.O. Box 1489, Sun Valley, California 91353
Resident Engineer: Russell Moussavian Structure Rep.: Raymond Barajas
Sample Information
DIME Sample ID: 2019-03-25-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 03/25/2019
Date that the sample was received by the laboratory/organization performing the testing: 03/25/2019
The quantity of what the sample constitutes: 30 all thread bars 50' long
A brief description of the sample: Threaded Bar
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form San Diego
Material Information
Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 150
Threaded Bar Type: Deformed
Rebar Size: 11
Nut Specification for Threaded Bar: A29 Grade 1045
System Manufacturer: Williams Form Engineering
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: Uncoated
Bar Heat Number(s): 10884671
Nut Heat Number(s): 75071080
Bar Lot Number: NA
Nut Lot Number: 36A9D
Coupler Heat Number(s): NA
Coupler Grade: NA
Test Results
Test 1 of 1
DIME Test ID: 2019-03-25-1-1
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 04/12/2019
Date Tested: 04/12/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples
|
2
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By | 1 | 1 3/8 | 10884671 | 1.50430 | 153981 | 83668 | 9.09 | 53.18 | A722 Bar Heat 10884671, Nut Heat 75071080 | FSaylor | 2 | 1 3/8 | 10884671 | 1.58 | 165722 | 144418 | 9.09 | 53.18 | A722 Bar Heat 10884671, Nut Heat 75071080 | FSaylor |
| |
Temperature
|
72 f
|
UTM
|
2000KIP
|