Sample Record for 2019-02-19-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 209695 DEA: 08347704 EFIS: 0800000616 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-SR-58-0/12.9
Work Description: (Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location Description: SR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Contractor Name: KIEWIT INFRASTRUCTURE WEST CO.
Contractor Address: 2215 E 1ST STREET, VANCOUVER, WA 98661
Resident Engineer: Shaine Shahidi Structure Rep.: Osama Abdalla

Sample Information

DIME Sample ID: 2019-02-19-6
TL Number from the TL Form: 1-2-19-19
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 02/19/2019
Date that the sample was received by the laboratory/organization performing the testing: 02/20/2019
The quantity of what the sample constitutes: 2
A brief description of the sample: Lean Concrete Base
From where was the sample collected: Fabricator
Laboratory sample identification: 976-219
Structure unique identifier: LB18 0031 7day break
Structure name: LB18 0031 7day break
The fabricator/manufacturer/facility name: Kiewit Infrastructure West

Material Information

The concrete mix design number: LB18-0031
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: 13713
Concrete batch plant: Kiewit
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: Kiewit PLant
Where the material sample would have been placed if not sampled: Sta 104 53 EB Exit Ramp
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2019-02-19-6-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 02/27/2019
Date Tested: 02/26/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 740 psi
Maximum load on cylinder 1 20190 lb
Maximum load on cylinder 2 21510 lb
Compressive strength of cylinder 1 714.2 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 760.9 psi
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data