Print Report | Back to Sample Detail

Sample Record for 2019-02-11-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213474 DEA: 010A8404 EFIS: 0113000058 QA Service Level: 1
DIST-CO-RTE-PM: 01-MEN-271-17.7/18.0
Work Description: BRIDGE REPLACEMENT, ROADWAY REALIGNMENT AND WIDENING.
Location Description: MENDOCINO COUNTY NEAR PIERCY FROM 0.7 MILE NORTH OF HIGHWAY 271/101 SEPARATION TO 0.4 MILE SOUTH OF THE SIDEHILL VIADUCT
Contractor Name: MERCER-FRASER COMPANY
Contractor Address: PO Box 1006, Eureka, CA 95502
Resident Engineer: Joaquin Rodriguez Structure Rep.: Peter O'Donnell

Sample Information

DIME Sample ID: 2019-02-11-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 02/11/2019
Date that the sample was received by the laboratory/organization performing the testing: 02/14/2019
The quantity of what the sample constitutes: 1
A brief description of the sample: bearing pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal Rubber

Material Information

Mfg. Lot Number(s): 17298-1
Material/Compound/Elastomer ID: na
Samples Representing: 17
Description (size): 2" x 18" x 18"
Comments: Unknown
Description (Number of Shims): 4
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: na

Test Results

Test 1 of 4

DIME Test ID: 2019-02-11-4-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 03/04/2019
Date Tested: 02/15/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 51
Reading #2 50
Reading #3 50
Reading #4 51
Reading #5 50
Mean 50.4

Test 2 of 4

DIME Test ID: 2019-02-11-4-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 03/04/2019
Date Tested: 02/15/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 11KIP
Humidity 50 %
Temperature no data f
Sample 1 Median Thickness 0.064 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2693.8 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.073 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2776 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.064 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2581.3 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2693.8 lbf/in^2

Test 3 of 4

DIME Test ID: 2019-02-11-4-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 03/04/2019
Date Tested: 02/15/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM no data
Humidity 50 %
Temperature no data f
Sample 1 Median Thickness 0.07 in
Sample 1 Tear Strength 240 lbf / in
Sample 2 Median Thickness 0.064 in
Sample 2 Tear Strength 251.6 lbf / in
Sample 3 Median Thickness 0.054 in
Sample 3 Tear Strength 248.1 lbf / in
Median of the Tear Strength Values 248.1 lb/in

Test 4 of 4

DIME Test ID: 2019-02-11-4-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 02/15/2019
Date Tested: 02/15/2019
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass