Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
DEA: No Project
QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2019-02-14-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 02/14/2019
Date that the sample was received by the laboratory/organization performing the testing: 02/21/2019
The quantity of what the sample constitutes: 1 lot of 21
A brief description of the sample: F3125 GR A325 MG Hex Bolt
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS Lindon UT
Rocap Number(s):
Heat Number(s): NF1520135352
Nut Mfg. Lot Number(s): M4342
Washer Mfg. Lot Number(s):
Bolt Specification: F3125/A325/A153/B695
Bolt Length(s): 4-1/2"
Nut Specification: N/A
Washer Specification: N/A
Finish: MG
Diameter/Size: 1-1/2"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2019-02-14-3-1
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 03/04/2019
Date Tested: 02/26/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 1A | M4342 | 1.5\" | 191147 | 850.3 | 6 | A325 | Steve |
| |
UTM
|
400KIP
|
Temperature
|
no data
|
DIME Test ID: 2019-02-14-3-2
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/04/2019
Date Tested: 02/27/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
M4342
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 UNY USA
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-02-14-3-3
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/04/2019
Date Tested: 02/27/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
M4342
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 UNY USA
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-02-14-3-4
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/04/2019
Date Tested: 02/27/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
M4342
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 UNY USA
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Gage Type
|
Pass
|
DIME Test ID: 2019-02-14-3-5
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/04/2019
Date Tested: 02/27/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
M4342
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 UNY USA
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Measurement Average
|
3.95 mils
|
DIME Test ID: 2019-02-14-3-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/04/2019
Date Tested: 02/27/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1B
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
M4342
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 UNY USA
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Measurement Average
|
6.28 mils
|
DIME Test ID: 2019-02-14-3-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/04/2019
Date Tested: 02/27/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1C
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
M4342
|
Finish Coating
|
ASTM B695 - Mech Galv
|
Product Markings
|
A325 UNY USA
|
Size
|
1.5 in
|
Bolt Length
|
4.5 in
|
Measurement Average
|
5.91 mils
|