Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-710-6.0-9.4
Work Description: Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location Description: Port of Long Beach (District 7)
Contractor Name: Shimmick/FCC/Impregilo (SFI) JV
Contractor Address: 11 Golden Shore, Suite 330, Long Beach, CA 90802
Resident Engineer: Structure Rep.: Sami Deeb
DIME Sample ID: 2019-02-08-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Independent Assurance
Type of Material: SMTL TM6 - Steel Check Sample Plate
Sample Taken Date: 02/08/2019
Date that the sample was received by the laboratory/organization performing the testing: 02/14/2019
The quantity of what the sample constitutes: 3056KG
A brief description of the sample: Check Sample Plates
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Stinger Bridge Iron
Heat Number(s): 811S09060
Material Specification: A709
Grade: HPS 50WF2
Thickness: .6875"
Shape: Rectangle
Metal Foundry Manufacturer (Mill): Arcelormittal Plate
Plate Dimension: 96" x 360"
DIME Test ID: 2019-02-08-1-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 03/05/2019
Date Tested: 02/19/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
2
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | | 811S09060 | 0.501 | 0.1971 | 59568 | 80580 | 28.2 | Fred | | 811S09060 | 0.502 | 0.1979 | 59260 | 79900 | 28.9 | Fred |
| |
UTM
|
67KIP
|
Temperature
|
72 F
|