Sample Record for 2019-01-08-2
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 209139 DEA: 071170U4 EFIS: 0700000085
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-33.2/37.2
Work Description: CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location Description: LOS ANGELES COUNTY IN BALDWIN PARK AND WEST COVINA FROM 0.1 MILE WEST OF PUENTE AVENUE UNDERCROSSING TO 0.2 MILE EAST OF HOLLENBECK STREET UNDERCROSSING
Contractor Name: Ames Construction, inc.
Contractor Address: 391 N Main Street, Suite 302, Corona, Ca 92880
Resident Engineer: Raj Punjabi Structure Rep.: Cardiel Bugarin
Sample Information
DIME Sample ID: 2019-01-08-2
TL Number from the TL Form: 14684
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 01/08/2019
Date that the sample was received by the laboratory/organization performing the testing: 01/14/2019
The quantity of what the sample constitutes: 2
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 882-684
Structure unique identifier: 736 Mod SW 1871 between st 1896 50 to 189775
Structure name: 736 Mod SW 1871 between st 1896 50 to 189775
The fabricator/manufacturer/facility name: holiday
Material Information
The concrete mix design number: CM5645
The truck number from where the sample was collected: 183
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: AMES CONSTRUCTION
A detailed description of where the material sample was collected: truck
Where the material sample would have been placed if not sampled: 736 Mod SW 1871 between st 1896 50 to 189775
From Lot No.: Unknown
Bag Lot No.: Unknown
Test Results
Test 1 of 1
DIME Test ID: 2019-01-08-2-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Verified Date: 02/06/2019
Date Tested: 02/05/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Compressive strength (to nearest 10 psi)
|
4540 psi
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Compressive strength of cylinder 1
|
4574.1 psi
|
Compressive strength of cylinder 2
|
4511.9 psi
|
Maximum load on cylinder 1
|
129310 lb
|
Maximum load on cylinder 2
|
127550 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
4
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
28 days
|