Project Information

Project ID: 212784 DEA: 023H1504 EFIS: 0217000064 QA Service Level: 1
DIST-CO-RTE-PM: 02-LAS-299-0.0/4.7
Work Description: AC OVERLAY, REPLACE ASPHALT CONCRETE SURFACING AND GUARDRAIL.
Location Description: LASSEN COUNTY NEAR MCARTHUR FROM SHASTA COUNTY LINE TO 4.0 MILES WEST OF MUCK VALLEY HYDRO ROAD.
Contractor Name: J.F. SHEA CONSTRUCTION, INC.
Contractor Address: 17400 Clearcreek Road, Redding, CA 96001
Resident Engineer: Tofael Anwar Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-05-31-19
TL Number from the TL Form: 736683
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 05/31/2018
Date that the sample was received by the laboratory/organization performing the testing: 05/31/2018
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: Combined RAP, 3/8-inch Minus
From where was the sample collected: Source
Laboratory sample identification: D77434
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Fawndale Rock and Asphalt

Material Information

RAP Source: Fawndale Rock and Asphalt, Redding, CA
Aggregate Size: 3/8-inch
Aggregate Source: Unknown
RAP Stockpile:
Stockpile Size (tons): Unknown
Reclaimed Asphalt Pavement Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2018-05-31-19-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 01/04/2019
Date Tested: 06/04/2018
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of HMA Sample prior to ignition no data
Corrected Asphalt Binder Content 5.78 %
Mass Loss no data
Correction Factor (Percent by mass of HMA Specimen) no data
Moisture Content no data
Temperature Compensation Factor no data
Test Temperature no data

Test 2 of 3

DIME Test ID: 2018-05-31-19-2
Test Method: AASHTO T30-15: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 01/04/2019
Date Tested: 06/04/2018
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Cumulative percent passing the 2 in. sieve no data
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 97.6 %
Cumulative percent passing the 1/4 in. sieve 80 %
Cumulative percent passing the #4 sieve 67.7 %
Cumulative percent passing the #8 sieve 45.7 %
Cumulative percent passing the #16 sieve 31.8 %
Cumulative percent passing the #30 sieve 23.4 %
Cumulative percent passing the #50 sieve 17.3 %
Cumulative percent passing the #100 sieve 13 %
Cumulative percent passing the #200 sieve 10.28 %

Test 3 of 3

DIME Test ID: 2018-05-31-19-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 01/04/2019
Date Tested: 06/06/2018
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Specific Gravity for Sample 1 2.562
Theoretical maximum density at 25°C (77°F) no data