Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 044H2104 Cty SM Rte 1 PM 37.9/R48.0 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Marcus Washington |
Date Reported: |
12/28/2018 |
|
Address: |
TL Number: |
201665 |
||
City: |
||||
Project Name: ASPHALT CONCRETE SURFACING, GRIND PCC PAVEMENT. |
||||
Prime Contractor: GRANITE ROCK COMPANY |
||||
Sample Taken Date: |
12/07/2018 |
Mix Design: |
D2Q115EA |
|
Contractor: Unknown |
Location: SAN MATEO COUNTY NEAR MONTARA, IN PACIFICA AND DALY CITY FROM 1.3 MILES NORTH OF 2ND STREET TO ROUTE 280 |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.02 | 28.46 | 145036 | 5096.1 | 1 |
2 | 6.00 | 28.27 | 141962 | 5021.6 | 1 |
DIME Test ID: 2018-12-07-6-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5060
Age of specimen: 21 days
Certified By: Larry McCrum
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing