Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212997 DEA: 023H2104 EFIS: 0217000070
QA Service Level: 1
DIST-CO-RTE-PM: 02-PLU-70,89-53.5/58.4,21.0/29.9
Work Description: AC OVERLAY, REPLACE AC SURFACE, GUARDRAIL, SHOULDER BACKING
Location Description: PLUMAS COUNTY ON ROUTE 70 FROM GREENHORN RANCH ROAD TO 0.2 MILE EAST OF SLOAT ROAD AND ON ROUTE 89 FROM 0.3 MILE SOUTH OF ALTA CAMP ROAD TO CANYON DAM PICNIC AREA
Contractor Name: LAMON CONSTRUCTION
Contractor Address: 871 Von Geldern Way, Yuba City , CA 95991
Resident Engineer: Ronald Collins Structure Rep.: Unknown
DIME Sample ID: 2018-05-22-23
TL Number from the TL Form: 894815
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Verification
Type of Material: Reclaimed Asphalt Pavement
Sample Taken Date: 05/22/2018
Date that the sample was received by the laboratory/organization performing the testing: 05/23/2018
The quantity of what the sample constitutes: JMF Verification
A brief description of the sample: Combined RAP
From where was the sample collected: Manufacturer
Laboratory sample identification: D77416
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Lockwood Hot Plant
RAP Source: Lockwood Hot Plant
Aggregate Size: 3/8-inch
Aggregate Source: Unknown
RAP Stockpile: Continuous
Stockpile Size (tons): 20000
Reclaimed Asphalt Pavement Mix Number:
DIME Test ID: 2018-05-22-23-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 12/17/2018
Date Tested: 05/25/2018
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
no data
|
Corrected Asphalt Binder Content
|
6.62 %
|
Mass Loss
|
no data
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data
|
Moisture Content
|
no data
|
Temperature Compensation Factor
|
no data
|
Test Temperature
|
no data
|
DIME Test ID: 2018-05-22-23-2
Test Method: AASHTO T30-15: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 12/17/2018
Date Tested: 05/28/2018
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Cumulative percent passing the 2 in. sieve
|
no data
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 3/8 in. sieve
|
94.4 %
|
Cumulative percent passing the 1/4 in. sieve
|
78.9 %
|
Cumulative percent passing the #4 sieve
|
69 %
|
Cumulative percent passing the #8 sieve
|
49.9 %
|
Cumulative percent passing the #16 sieve
|
37.2 %
|
Cumulative percent passing the #30 sieve
|
27.9 %
|
Cumulative percent passing the #50 sieve
|
20 %
|
Cumulative percent passing the #100 sieve
|
14.3 %
|
Cumulative percent passing the #200 sieve
|
10.5 %
|
DIME Test ID: 2018-05-22-23-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 12/17/2018
Date Tested: 05/27/2018
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Specific Gravity for Sample 1
|
2.501
|
Theoretical maximum density at 25°C (77°F)
|
no data
|