Print Report | Back to Sample Detail

Sample Record for 2018-12-10-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-12-10-3
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 12/10/2018
Date that the sample was received by the laboratory/organization performing the testing: 12/12/2018
The quantity of what the sample constitutes: 2
A brief description of the sample: Epoxy Coated Rebar
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Nucor

Material Information

Rebar Heat Number(s): 1202008359
Rebar Epoxy Batch Number(s):
Rebar Coating Specification: ASTM A775
Rebar Size (#): 4
Rebar Coating Color: Green
Rebar Manufacturer: Nucor
Rebar Coater: Western Coating
Rebar Powder Manufacturer: AkzoNobel
Release Number: Unknown
Quality Assurance Code: Unknown

Test Results

Test 1 of 2

DIME Test ID: 2018-12-10-3-1
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 12/14/2018
Date Tested: 12/13/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean 8.21
Second Bar Mean 8.51
Lower spec. limit LSL 7
Upper spec. limit USL 12
Bar # for First Bar 1
Bar # for Second Bar 2
Total mean value 8.36
Total number of values less than LSL no data
Total number of values greater than USL no data

Test 2 of 2

DIME Test ID: 2018-12-10-3-2
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 12/14/2018
Date Tested: 12/13/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday 1
Total Length 5
Holidays Per Linear Foot of Bar 0.2
Holiday Test Pass/Fail Pass
Bend Test Pass/Fail Pass