Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213516 DEA: 101H3414 EFIS: 1018000077
QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-5-R21.4
Work Description: GIRDER REPAIR.
Location Description: SAN JOAQUIN COUNTY AT FRENCH CAMP AT MATHEWS ROAD UNDERCROSSING
Contractor Name: MCM Construction
Contractor Address: P.O. Box 620, North Highlands, CA 95660
Resident Engineer: (Abdul) Obaidullah Rashid Structure Rep.: Daniel Laureno
DIME Sample ID: 2018-12-11-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 12/11/2018
Date that the sample was received by the laboratory/organization performing the testing: 12/13/2018
The quantity of what the sample constitutes: 2 partial packs
A brief description of the sample: .6" 270ksi strand
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Schwager-Davis
Comments: Unknown
Reel/Coil/Pack Number(s): S378233-4
S334180-2
Number of Coils: 2 partials
Group Number: Unknown
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0201504
s0520317
Mfg. Lot Number(s): unknown at this time
Manufacturer(s): Sumiden
DIME Test ID: 2018-12-11-1-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 12/20/2018
Date Tested: 12/19/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0201504 | S378235-4 | 0.215 | 58909 | 53796 | 28.1 | 1.79 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
72 F
|
Extensometers
|
E88768
|
DIME Test ID: 2018-12-11-1-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 12/20/2018
Date Tested: 12/19/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | S0520317 | S334180-2 | 0.215 | 61214 | 55908 | 28.8 | 1.74 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
72 F
|
Extensometers
|
E88768
|