DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 04013584 Cty SF Rte 80 PM 8.0/8.3,0.9/1.4 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Brian Boal |
Date Reported: |
12/04/2018 |
|
Address: |
TL Number: |
Unknown |
||
City: |
||||
Project Name: Pier Retention |
||||
Prime Contractor: Kiewit/Manson, AJV |
||||
Sample Taken Date: |
11/06/2018 |
Mix Design: |
4E01C588 |
|
Contractor: Unknown |
Location: In San Francisco and Alameda Counties on Yerba Buena Island and .4 miles west of Oakland Toll plaza |
|||
Structure unique identifier: Unknown |
||||
Structure name: Oakland Observation Structure |
||||
Location of Pour: Span1 to 2 Closure Pour Deck |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.03 | 28.56 | 166237 | 5820.6 | 1 |
2 | 6.02 | 28.46 | 167958 | 5901.5 | 1 |
DIME Test ID: 2018-11-06-6-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5860
Age of specimen: 28 days
Certified By: Larry McCrum
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.37 | 115999 | 4088.8 | 1 |
2 | 6.03 | 28.56 | 117843 | 4126.2 | 1 |
DIME Test ID: 2018-11-06-6-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4110
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 7 days
Certified By: Larry McCrum
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing