Print Report | Back to Sample Detail

Sample Record for 2018-10-26-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213491 DEA: 031H6104 EFIS: 0316000190 QA Service Level: 1
DIST-CO-RTE-PM: 03---
Work Description: METS is performing preliminary field investigation and testing to help design choose a retrofitting plan for the Sacramento West End Viaduct.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-10-26-4
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Per Request
Type of Material: SMTL TM6 - Steel Check Sample Plate
Sample Taken Date: 10/26/2018
Date that the sample was received by the laboratory/organization performing the testing: 10/26/2018
The quantity of what the sample constitutes: 1
A brief description of the sample: 3" x 8" Coupon
From where was the sample collected: Job Site
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Unknown

Material Information

Heat Number(s): Unknown
Material Specification: A709
Grade: Unknown
Thickness: 0.3125
Shape: Rectangle
Metal Foundry Manufacturer (Mill): Unknown
Plate Dimension: Unknown

Test Results

Test 1 of 2

DIME Test ID: 2018-10-26-4-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Flat Sample)
Verified Date: 11/02/2018
Date Tested: 10/31/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 2
SampleHeat NumberWidth (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Total Elongation (%)Tested By
N/A0.5010.1754372105999439.2Fred
N/A0.5050.1768376375961538.1Fred
UTM 67KIP
Temperature 72 F

Test 2 of 2

DIME Test ID: 2018-10-26-4-2
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 11/02/2018
Date Tested: 11/01/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number no data
Finish Coating Plain
Product Markings no data
Size no data in
Bolt Length no data in
Hardness Reading Scale B Scale
Hardness Reading Average 71.84
Spacing Ok