Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 040A7104 Cty ALA Rte 880 PM 28.4/29.2 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Joy Cheung |
Date Reported: |
12/05/2018 |
|
Address: |
TL Number: |
195984 |
||
City: |
||||
Project Name: WIDEN ROADS, RECONSTRUCT RAMPS WITH HMA, REPLACE 2 CONC OVERCROSSINGS. |
||||
Prime Contractor: RGW Construction |
||||
Sample Taken Date: |
10/24/2018 |
Mix Design: |
1517949 |
|
Contractor: Unknown |
Location : ALAMEDA COUNTY IN ALAMEDA AND OAKLAND FROM 0.2 MILE SOUTH OF 29TH AVENUE OVERCROSSING TO 0.3 MILE NORTH OF 23RD AVENUE OVERCROSSING. |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.03 | 28.56 | 125723 | 4402.1 | 1 |
2 | 6.02 | 28.46 | 125517 | 4410.3 | 1 |
DIME Test ID: 2018-10-24-12-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4410
Age of specimen: 7 days
Certified By: Larry McCrum
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.02 | 28.46 | 142481 | 5006.4 | 1 |
2 | 6.02 | 28.46 | 150751 | 5296.9 | 1 |
DIME Test ID: 2018-10-24-12-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5150
Age of specimen: 28 days
Certified By: Larry McCrum
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.37 | 159489 | 5621.7 | 1 |
2 | 6.01 | 28.37 | 161608 | 5696.4 | 1 |
DIME Test ID: 2018-10-24-12-3
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5660
Age of specimen: 21 days
Certified By: Larry McCrum
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.37 | 172952 | 6096.3 | 1 |
2 | 6.01 | 28.37 | 183596 | 6471.5 | 1 |
DIME Test ID: 2018-10-24-12-4
Number of specimens: 2
Compressive strength (to nearest 10 psi): 6280
Age of specimen: 28 days
Certified By: Larry McCrum
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.04 | 28.65 | 206706 | 7214.9 | 1 |
2 | 6.01 | 28.37 | 202043 | 7121.7 | 1 |
DIME Test ID: 2018-10-24-12-5
Number of specimens: 2
Compressive strength (to nearest 10 psi): 7170
Age of specimen: 42 days
Certified By: Larry McCrum
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing