Print Report | Back to Sample Detail

Sample Record for 2018-09-28-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-09-28-8
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 09/28/2018
Date that the sample was received by the laboratory/organization performing the testing: 10/02/2018
The quantity of what the sample constitutes: 8
A brief description of the sample: Ductile Iron Casting
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SDI Farrar

Material Information

Heat Number (s): G118, G128, G138, G208, H028, H098, H098, H10
Part Number (s): 27 6 AH 27 6 PC BP 19 6 PCI BP 19 6 PC1 BP F
Material Specification: A536
Grades: 80-55-06
Metal Foundry Manufacturer (Mill): Farrar Corporation
Prestressing Manufacturer: SDI

Test Results

Test 1 of 1

DIME Test ID: 2018-09-28-8-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 10/10/2018
Date Tested: 10/05/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 8
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
G1180.5010.1971650401147608.1Fred
G1280.5010.1971650651136308.6Fred
G1380.5010.1971630931078509.6Fred
G2080.50.1963608311057409.6Fred
H0280.5010.1971615121064109.7Fred
H0980.50.1963615001075109.7Fred
H0980.5010.1971616751057709.8Fred
H1080.5010.19716346311107011Fred
UTM 67KIP
Temperature 72 F