Print Report | Back to Sample Detail

Sample Record for 2018-09-21-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210837 DEA: 080J0804 EFIS: 0800000283 COOP: 081625 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-34.7/51.6
Work Description: (Alternative Delivery) DESIGN-BUILD OF THE INTERSTATE 15 EXPRESS LANES PROJECT
Location Description: Riverside County and SBD-15-0.0/1.3
Contractor Name: Skanska-Ames, Joint Venture
Contractor Address: 1801 California Avenue, Corona, CA 92881
Resident Engineer: Roy Fisher (reports) Structure Rep.: Roy Fisher

Sample Information

DIME Sample ID: 2018-09-21-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: 5625005861
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 09/21/2018
Date that the sample was received by the laboratory/organization performing the testing: 09/24/2018
The quantity of what the sample constitutes: 2 coated bars only
A brief description of the sample: 8 A706 epoxy coated rebar
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Integrity Rebar

Material Information

Rebar Heat Number(s): PL17107178
Rebar Epoxy Batch Number(s): UE88305NA
Rebar Coating Specification: ASTM A775
Rebar Size (#): 8
Rebar Coating Color: Green
Rebar Manufacturer: NUCOR
Rebar Coater: WESTERN COATING
Rebar Powder Manufacturer: AKZOnOBEL
Release Number: n/a
Quality Assurance Code: n/a

Test Results

Test 1 of 2

DIME Test ID: 2018-09-21-1-1
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 09/26/2018
Date Tested: 09/25/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
First Bar Mean 8.68
Second Bar Mean 8.96
Lower spec. limit LSL 7
Upper spec. limit USL 16
Bar # for First Bar 1
Bar # for Second Bar 2
Total mean value 8.82
Total number of values less than LSL no data
Total number of values greater than USL no data

Test 2 of 2

DIME Test ID: 2018-09-21-1-2
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 09/26/2018
Date Tested: 09/25/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday 0
Total Length 2.6
Holidays Per Linear Foot of Bar 0
Holiday Test Pass/Fail Pass
Bend Test Pass/Fail Pass