Project ID: 213237 DEA: 081G8204 EFIS: 0816000078
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-38-3.8/15.0
Work Description: OVERLAY RUBBERIZED HOT MIX ASPHALT AND UPGRADE ADA RAMPS
Location Description: SAN BERNARDINO COUNTY IN AND NEAR REDLANDS FROM AGATE AVENUE TO VALLEY OF THE FALLS DRIVE
Contractor Name: All American Asphalt
Contractor Address: PO BOX 2229, Corona, CA 92878
Resident Engineer: Nhan Nguyen Structure Rep.: Unknown
DIME Sample ID: 2018-08-27-5
TL Number from the TL Form: 20180827
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/27/2018
Date that the sample was received by the laboratory/organization performing the testing: 08/28/2018
The quantity of what the sample constitutes: 6
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 986-0827
Structure unique identifier: rte138and agate NW and NE spandrels and curbs
Structure name: rte138and agate NW and NE spandrels and curbs
The fabricator/manufacturer/facility name: Robertsons Rialto
The concrete mix design number: SC590B38
The truck number from where the sample was collected: 1551
The batch plant ticket number from where the sample was collected: 3955198
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: all american asphalt
A detailed description of where the material sample was collected: MIDLE OF LOAD
Where the material sample would have been placed if not sampled: rte138and agate NW and NE spandrels and curbs
From Lot No.: Unknown
Bag Lot No.: Unknown
DIME Test ID: 2018-08-27-5-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/07/2018
Date Tested: 09/04/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.01 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.37 in^2
|
Compressive strength (to nearest 10 psi)
|
2180 psi
|
Maximum load on cylinder 1
|
62140 lb
|
Maximum load on cylinder 2
|
61260 lb
|
Compressive strength of cylinder 1
|
2198.1 psi
|
Type of fracture pattern of cylinder 1
|
4
|
Compressive strength of cylinder 2
|
2159.3 psi
|
Type of fracture pattern of cylinder 2
|
4
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
8 days
|
Age of specimen in hours
|
no data
|
DIME Test ID: 2018-08-27-5-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/10/2018
Date Tested: 09/10/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.01 in
|
Average diameter of cylinder 2
|
6.02 in
|
Cross sectional area of cylinder 1
|
28.37 in^2
|
Cross sectional area of cylinder 2
|
28.46 in^2
|
Compressive strength (to nearest 10 psi)
|
13610 psi
|
Maximum load on cylinder 1
|
699920 lb
|
Maximum load on cylinder 2
|
72750 lb
|
Compressive strength of cylinder 1
|
24671.1 psi
|
Type of fracture pattern of cylinder 1
|
4
|
Compressive strength of cylinder 2
|
2556.2 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
14 days
|
Age of specimen in hours
|
no data
|