Print Report | Back to Sample Detail

Sample Record for 2018-07-26-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213152 DEA: 032F5904 EFIS: 0300020624 QA Service Level: 1
DIST-CO-RTE-PM: 03-YUB,NEV-20-20.1/21.7, 0.0/0.1
Work Description: CURVE REALIGNMENT AND SHOULDER WIDENING
Location Description: YUBA AND NEVADA COUNTIES NEAR SMARTSVILLE FROM 0.5 MILE WEST OF MCGANNEY LANE TO MOONEY FLAT ROAD
Contractor Name: Flatiron West, Incorporated
Contractor Address: 2100 Goodyear Road, Benicia, CA 94510
Resident Engineer: Aaron Chamberlin Structure Rep.: Justin Wood

Sample Information

DIME Sample ID: 2018-07-26-10
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 07/26/2018
Date that the sample was received by the laboratory/organization performing the testing: 07/31/2018
The quantity of what the sample constitutes: 10
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Dynamic Rubber

Material Information

Mfg. Lot Number(s): CR55-018-18, CR55-017-18
Material/Compound/Elastomer ID: NA
Samples Representing: 10
Description (size): 4.61" x 18" x 18"
Comments: Unknown
Description (Number of Shims): 8
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Dynamic Rubber
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2018-07-26-10-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 08/13/2018
Date Tested: 08/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 55
Reading #2 54
Reading #3 54
Reading #4 55
Reading #5 54
Mean 54.4

Test 2 of 4

DIME Test ID: 2018-07-26-10-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 08/13/2018
Date Tested: 08/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM 2KIP
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.065 in
Sample 1 Thickness all Within 0.003 inch? Yes
Sample 1 Ultimate Tensile 2331.3 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.065 in
Sample 2 Thickness all Within 0.003 inch? Yes
Sample 2 Ultimate Tensile 2331.3 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.063 in
Sample 3 Thickness all Within 0.003 inch? Yes
Sample 3 Ultimate Tensile 2594.9 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2331.3 lbf/in^2

Test 3 of 4

DIME Test ID: 2018-07-26-10-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 08/13/2018
Date Tested: 08/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM no data
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.071 in
Sample 1 Tear Strength 225.4 lbf / in
Sample 2 Median Thickness 0.064 in
Sample 2 Tear Strength 359.4 lbf / in
Sample 3 Median Thickness 0.063 in
Sample 3 Tear Strength 349.2 lbf / in
Median of the Tear Strength Values 349.2 lb/in

Test 4 of 4

DIME Test ID: 2018-07-26-10-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 08/10/2018
Date Tested: 08/10/2018
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Result Pass