Print Report | Back to Sample Detail

Sample Record for 2018-08-02-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-08-02-2
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Verification
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 08/02/2018
Date that the sample was received by the laboratory/organization performing the testing: 08/03/2018
The quantity of what the sample constitutes: 1
A brief description of the sample: chisel pont all thread
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: UIS

Material Information

Rocap Number(s): none
Heat Number(s): 62145759
Nut Mfg. Lot Number(s): n/a
Washer Mfg. Lot Number(s): none
Bolt Specification: F1554 Gr.36
Bolt Length(s): 11"
Nut Specification: n/a
Washer Specification: n/a
Finish: HDG
Diameter/Size: 7/8" x 11"
Bolt Mfg. Lot Number: none
Rocap Test Requirement(s): none
Lubricant Requirements(s): none

Test Results

Test 1 of 1

DIME Test ID: 2018-08-02-2-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 08/09/2018
Date Tested: 08/09/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1621457590.4980.195844439708017.7Glen
UTM 67KIP
Temperature 72 f