Sample Record for 2018-07-06-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213032 DEA: 101G3304 EFIS: 1016000157 QA Service Level: 1
DIST-CO-RTE-PM: 10-MER-5,152-Var
Work Description: REPLACE JOINT SEALS, APPROACH SLABS, POLYESTER CONCRETE OVERLAY.
Location Description: MERCED COUNTY AT VARIOUS LOCATIONS.
Contractor Name: MYERS AND SONS CONSTRUCTION, LP
Contractor Address: 4600 NORTHGATE BLVD. SUITE 10, SACRAMENTO CA 95834
Resident Engineer: Muhammad Rahman Structure Rep.: Sam Singh

Sample Information

DIME Sample ID: 2018-07-06-7
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 594-1991
Type of Sample: Quality Assurance
Type of Material: Polyester
Sample Taken Date: 07/06/2018
Date that the sample was received by the laboratory/organization performing the testing: 07/06/2018
The quantity of what the sample constitutes: 80 drums
A brief description of the sample: polyester
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KBP

Material Information

Mfg. Lot Number(s): 0001129648
Batch number: 0001129648
Mix number: 3326

Test Results

Test 1 of 1

DIME Test ID: 2018-07-06-7-1
Test Method: CONCLP 3-16: Polyester Resin
Verified Date: 07/27/2018
Date Tested: 07/27/2018
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: accepted suppliers results
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F 105
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35% 64.7
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi 3017
Styrene ASTM D 2369 40% to 50 % 45.6
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours 799
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams 0.1