Print Report | Back to Sample Detail

Sample Record for 2018-07-26-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212562 DEA: 024G5504 EFIS: 0214000036 QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-5-2.7/R11.4
Work Description: RECONSTRUCT WITH HMA AND PCC, WIDEN STRUCTURE AND UPGRADE RAILS
Location Description: SISKIYOU COUNTY IN AND NEAR DUNSMUIR FROM SACRAMENTO RIVER BRIDGE TO 0.6 MILE SOUTH OF NORTH MOUNT SHASTA UNDERPASS
Contractor Name: J.F. SHEA CONSTRUCTION
Contractor Address: P.O. BOX 494519, REDDING, CA 96049-4519
Resident Engineer: Nicole Mallory Structure Rep.: Andrew Osullivan

Sample Information

DIME Sample ID: 2018-07-26-3
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 07/26/2018
Date that the sample was received by the laboratory/organization performing the testing: 07/26/2018
The quantity of what the sample constitutes: 1700
A brief description of the sample: Loose Tie Bars
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: JC Supply Manufacturing

Material Information

Rebar Heat Number(s): PL16206939
Rebar Epoxy Batch Number(s): 8496026962
Rebar Coating Specification: ASTM A934
Rebar Size (#): 6
Rebar Coating Color: Purple
Rebar Manufacturer: Nucor
Rebar Coater: JC Supply And Manufacturing
Rebar Powder Manufacturer: Valspar
Release Number: Unknown
Quality Assurance Code: Unknown

Test Results

Test 1 of 2

DIME Test ID: 2018-07-26-3-1
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 08/08/2018
Date Tested: 08/08/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL 7 mils
Upper spec. limit USL 12 mils
Bar # for First Bar 1
Bar # for Second Bar 2
First Bar Mean 8.63 mils
Second Bar Mean 7.44 mils
Total mean value 8.03 mils

Test 2 of 2

DIME Test ID: 2018-07-26-3-2
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Holiday Bend)
Verified Date: 08/08/2018
Date Tested: 08/08/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday 0
Total Length 5 ft
Holidays Per Linear Foot of Bar 0 holiday pe
Holiday Test Pass/Fail Pass
Bend Test Pass/Fail Pass