Print Report | Back to Sample Detail

Sample Record for 2018-07-12-16

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-07-12-16
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Informational
Type of Material: SMTL TM6 - Steel Check Sample Plate
Sample Taken Date: 07/12/2018
Date that the sample was received by the laboratory/organization performing the testing: 07/12/2018
The quantity of what the sample constitutes: 1
A brief description of the sample: Ferry Swivel Tube
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Unknown

Material Information

Heat Number(s): Unknown
Material Specification: A36
Grade: Unknown
Thickness: .625 Wall
Shape: Round
Metal Foundry Manufacturer (Mill): Unknown
Plate Dimension: 2.5" OD Tube

Test Results

Test 1 of 1

DIME Test ID: 2018-07-12-16-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Flat Sample)
Verified Date: 07/30/2018
Date Tested: 07/25/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 2
SampleHeat NumberWidth (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Total Elongation (%)Tested By
N/A0.5040.1583425346531937.6Brian
N/A0.5010.1573449216647835.5Brian
UTM 67KIP
Temperature 72 F