Print Report | Back to Sample Detail

Sample Record for 2018-07-23-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213267 DEA: 04013584 EFIS: 0416000289 QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-80-8.0/8.3,0.9/1.4
Work Description: Pier Retention
Location Description: In San Francisco and Alameda Counties on Yerba Buena Island and .4 miles west of Oakland Toll plaza
Contractor Name: Kiewit/Manson, AJV
Contractor Address: 4650 Business Center Drive, Fairfield,CA 94804
Resident Engineer: Brian Boal Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-07-23-3
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Department Acceptance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 07/23/2018
Date that the sample was received by the laboratory/organization performing the testing: 07/26/2018
The quantity of what the sample constitutes: 860 lbs.
A brief description of the sample: Epoxy coated prefabricated rebar
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Bellis Steel

Material Information

Rebar Heat Number(s): 4073765
Rebar Epoxy Batch Number(s): 8D09 and 8D10
Rebar Coating Specification: ASTM A934
Rebar Size (#): 10
Rebar Coating Color: Purple
Rebar Manufacturer: 3M
Rebar Coater: Fletcher Coating Company
Rebar Powder Manufacturer: Unknown
Release Number:
Quality Assurance Code: A934158G20R2S18D09 A934158G19R2S18D09 A93415

Test Results

Test 1 of 2

DIME Test ID: 2018-07-23-3-1
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 08/06/2018
Date Tested: 07/27/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL 7 mils
Upper spec. limit USL 12 mils
Bar # for First Bar 10A
Bar # for Second Bar 10B
First Bar Mean 8.28
Second Bar Mean 8.97
Total mean value 8.62

Test 2 of 2

DIME Test ID: 2018-07-23-3-2
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Holiday Bend)
Verified Date: 08/06/2018
Date Tested: 07/27/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday 0
Total Length 2.6
Holidays Per Linear Foot of Bar 0
Holiday Test Pass/Fail Pass
Bend Test Pass/Fail Pass