Print Report | Back to Sample Detail

Sample Record for 2018-07-18-19

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212618 DEA: 044G0564 EFIS: 0417000154 QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-680-M2.4/M12.4
Work Description: ROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS
Location Description: FREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING
Contractor Name: BAY CITIES PAVING & GRADING, INC.
Contractor Address: 1450 Civic Ct. BLDG B #400, Concord CA, 94520
Resident Engineer: Yannaing Tun Structure Rep.: Jordan Jarosz

Sample Information

DIME Sample ID: 2018-07-18-19
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Acceptance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 07/18/2018
Date that the sample was received by the laboratory/organization performing the testing: 07/20/2018
The quantity of what the sample constitutes: 4 coating dates
A brief description of the sample: A934 Purple Epoxy Coated Rebar
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Eng

Material Information

Production or Authorization Testing: Retest
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Deformed
Rebar Size: 9
Nut Specification for Threaded Bar: Not applicable
System Manufacturer: Williams Form Engineering
Epoxy Coating Color: Purple
Threaded Bar Application: Soil Nail
Coating Standards: ASTM A934 epoxy
Bar Heat Number(s): 100792512, 100891184
Nut Heat Number(s): Not applicable
Bar Lot Number: See emailed document
Nut Lot Number: Not applicable
Coupler Heat Number(s): Not applicable
Coupler Grade: Not applicable

Test Results

Test 1 of 4

DIME Test ID: 2018-07-18-19-1
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 07/26/2018
Date Tested: 07/25/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL 10 mils
Upper spec. limit USL 15 mils
Bar # for First Bar 100891184-A1
Bar # for Second Bar 100891184-B1
First Bar Mean 11.78 mils
Second Bar Mean 10.63 mils
Total mean value 11.2 mils

Test 2 of 4

DIME Test ID: 2018-07-18-19-2
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 07/26/2018
Date Tested: 07/25/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL 10 mils
Upper spec. limit USL 15 mils
Bar # for First Bar 100891184-A2
Bar # for Second Bar 100891184-B2
First Bar Mean 11.79
Second Bar Mean 12.54
Total mean value 12.16

Test 3 of 4

DIME Test ID: 2018-07-18-19-3
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 07/26/2018
Date Tested: 07/25/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL 10 mils
Upper spec. limit USL 15 mils
Bar # for First Bar 100891184-A3
Bar # for Second Bar 100891184-B3
First Bar Mean 9.64
Second Bar Mean 11.76
Total mean value 10.7

Test 4 of 4

DIME Test ID: 2018-07-18-19-4
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 07/26/2018
Date Tested: 07/25/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL 10 mils
Upper spec. limit USL 15 mils
Bar # for First Bar 100792512-A4
Bar # for Second Bar 100792512-B4
First Bar Mean 9.98
Second Bar Mean 10.59
Total mean value 10.29