Sample Record for 2018-07-11-9

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211712 DEA: 07305204 EFIS: 0714000092 QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-33-15.7
Work Description: CONSTRUCT SOIL NAIL WALL AND ROCK SLOPE PROTECTION.
Location Description: VENTURA COUNTY NEAR OJAI AT 0.1 MILE SOUTH OF NORTH FORK MATILIJA CREEK BRIDGE
Contractor Name: C. A. RASMUSSEN, INC.
Contractor Address: 28548 Livingston Ave, Valencia, CA 91355
Resident Engineer: Alfred Ira Structure Rep.: Pantaleon Rivera

Sample Information

DIME Sample ID: 2018-07-11-9
TL Number from the TL Form: 984-627
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/11/2018
Date that the sample was received by the laboratory/organization performing the testing: 07/13/2018
The quantity of what the sample constitutes: 6
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 984-627
Structure unique identifier: RT33 FAILURE SLOPE REPAIR
Structure name: RT33 FAILURE SLOPE REPAIR
The fabricator/manufacturer/facility name: PALMDALE

Material Information

The concrete mix design number: 3F362001
The truck number from where the sample was collected: NA
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: RASMUSSEN
A detailed description of where the material sample was collected: NA
Where the material sample would have been placed if not sampled: RT33 FAILURE SLOPE REPAIR
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 3

DIME Test ID: 2018-07-11-9-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/18/2018
Date Tested: 07/18/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 2950 psi
Maximum load on cylinder 1 83890 lb
Maximum load on cylinder 2 83025 lb
Compressive strength of cylinder 1 2967.5 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 2936.9 psi
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data

Test 2 of 3

DIME Test ID: 2018-07-11-9-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/08/2018
Date Tested: 08/08/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.02 in
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.46 in^2
Compressive strength (to nearest 10 psi) 3870 psi
Maximum load on cylinder 1 113560 lb
Maximum load on cylinder 2 106550 lb
Compressive strength of cylinder 1 3990.2 psi
Type of fracture pattern of cylinder 1 4
Compressive strength of cylinder 2 3743.9 psi
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours no data

Test 3 of 3

DIME Test ID: 2018-07-11-9-3
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/05/2018
Date Tested: 09/05/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.03 in
Average diameter of cylinder 2 6.03 in
Cross sectional area of cylinder 1 28.56 in^2
Cross sectional area of cylinder 2 28.56 in^2
Compressive strength (to nearest 10 psi) 4480 psi
Maximum load on cylinder 1 128000 lb
Maximum load on cylinder 2 128150 lb
Compressive strength of cylinder 1 4481.8 psi
Type of fracture pattern of cylinder 1 4
Compressive strength of cylinder 2 4487.0 psi
Type of fracture pattern of cylinder 2 4
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 56 days
Age of specimen in hours no data