Sample Record for 2018-07-02-1
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 213267 DEA: 04013584 EFIS: 0416000289
QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-80-8.0/8.3,0.9/1.4
Work Description: Pier Retention
Location Description: In San Francisco and Alameda Counties on Yerba Buena Island and .4 miles west of Oakland Toll plaza
Contractor Name: Kiewit/Manson, AJV
Contractor Address: 4650 Business Center Drive, Fairfield,CA 94804
Resident Engineer: Brian Boal Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2018-07-02-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 07/02/2018
Date that the sample was received by the laboratory/organization performing the testing: 07/06/2018
The quantity of what the sample constitutes: 40973 lbs.
A brief description of the sample: 4, 5 and 6 Purple Epoxy Rebars
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Fletcher Coating Co
Material Information
Rebar Heat Number(s): 124118, 4075926 and 160918
Rebar Epoxy Batch Number(s): 8D09 and 8D10
Rebar Coating Specification: ASTM A934
Rebar Size (#): 4, 5 and 6
Rebar Coating Color: Purple
Rebar Manufacturer: Cascade Steel,CMC Steel AZ
Rebar Coater: Fletcher Coating Company
Rebar Powder Manufacturer: 3M
Release Number: Unknown
Quality Assurance Code: A93418F28R2S18D09 and A93418F
Test Results
Test 1 of 6
DIME Test ID: 2018-07-02-1-1
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 07/11/2018
Date Tested: 07/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL
|
7 mils
|
Upper spec. limit USL
|
12 mils
|
Bar # for First Bar
|
4A
|
Bar # for Second Bar
|
4B
|
First Bar Mean
|
9.8
|
Second Bar Mean
|
9.49
|
Total mean value
|
9.64
|
Test 2 of 6
DIME Test ID: 2018-07-02-1-2
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Holiday Bend)
Verified Date: 07/11/2018
Date Tested: 07/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
no data0
|
Total Length
|
2.6
|
Holidays Per Linear Foot of Bar
|
no data0 holiday per ft
|
Holiday Test Pass/Fail
|
Pass
|
Bend Test Pass/Fail
|
Pass
|
Test 3 of 6
DIME Test ID: 2018-07-02-1-3
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 07/11/2018
Date Tested: 07/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL
|
7 mils
|
Upper spec. limit USL
|
12 mils
|
Bar # for First Bar
|
5A
|
Bar # for Second Bar
|
5B
|
First Bar Mean
|
10.07
|
Second Bar Mean
|
10.1
|
Total mean value
|
10.09
|
Test 4 of 6
DIME Test ID: 2018-07-02-1-4
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Holiday Bend)
Verified Date: 07/11/2018
Date Tested: 07/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
2
|
Total Length
|
2.6
|
Holidays Per Linear Foot of Bar
|
0.8
|
Holiday Test Pass/Fail
|
Pass
|
Bend Test Pass/Fail
|
Pass
|
Test 5 of 6
DIME Test ID: 2018-07-02-1-5
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Verified Date: 07/11/2018
Date Tested: 07/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Lower spec. limit LSL
|
7 mils
|
Upper spec. limit USL
|
12 mils
|
Bar # for First Bar
|
6A
|
Bar # for Second Bar
|
6B
|
First Bar Mean
|
10.04
|
Second Bar Mean
|
9.83
|
Total mean value
|
9.94
|
Test 6 of 6
DIME Test ID: 2018-07-02-1-6
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Holiday Bend)
Verified Date: 07/11/2018
Date Tested: 07/10/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total Number of Holiday
|
no data0
|
Total Length
|
2.6
|
Holidays Per Linear Foot of Bar
|
no data0 holiday per ft
|
Holiday Test Pass/Fail
|
Pass
|
Bend Test Pass/Fail
|
Pass
|